Embedding a multichannel <scp>ion‐sensitive field‐effect transistor</scp>‐<scp>pH</scp> sensor array in marine sediments: a new approach for continuous in situ <scp>pH</scp> monitoring

Abstract Human activities have significantly increased carbon dioxide emissions, leading to global warming and ocean acidification, which threaten marine ecosystems, including coral reefs with high biodiversity. Coral reef maintenance relies on a balance between calcium carbonate formation and dissolution. Among the processes, sandy sediments, covering vast areas and highly sensitive to ocean acidification, require urgent investigations to elucidate their dissolution mechanisms. However, conventional glass electrodes have limitations in continuous monitoring of the spatiotemporal distribution of pH within sediment. To address this, we developed a multichannel ion‐sensitive field‐effect transistor (ISFET)‐pH sensor array with a tantalum oxide sensing membrane, which was embedded in the sediment to enable high‐resolution and continuous pH monitoring. A 24‐h pH monitoring experiment was conducted in coral reef sediments to validate the method. The performance of the sensor was evaluated through both laboratory and field observations, and a comparison with a conventional glass electrode confirmed that the ISFET‐pH sensor provided stable pH measurements within the uncertainty range of the glass electrode. The developed sensor array is a low‐cost and durable automatic measurement system, offering an alternative to conventional glass electrodes, which are expensive and fragile. However, optimizing sputtering conditions, annealing processes, and data processing techniques is necessary to reduce environmental influences and enhance measurement accuracy. The proposed array‐based observation method enables the acquisition of high‐resolution vertical pH profiles and is expected to contribute to the quantitative evaluation of the chemical role of sandy sediments and the elucidation of carbon cycling in coral reef ecosystems.

Authors

Institutions

Publication Details

Journal
Limnology and Oceanography Methods
Published
2025-07-19
DOI
https://doi.org/10.1002/lom3.10709
Citations
1
Primary Topic
Ocean Acidification Effects and Responses
Type
article
Field-Weighted Citation Impact
1.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Embedding a multichannel ion‐sensitive field‐effect transistor‐pH sensor array in marine sediments: a new approach for continuous in situ pH monitoring

Kazuhiro Morioka, Hajime Kayanne, Akihide Hemmi, Yoko Ogawa et al.
1 citations
Limnology and Oceanography Methods
Ocean Acidification Effects and Responses
1.79
article

Embedding a multichannel ion‐sensitive field‐effect transistor‐pH sensor array in marine sediments: a new approach for continuous in situ pH monitoring

Kazuhiro Morioka, Hajime Kayanne, Akihide Hemmi, Yoko Ogawa, Kenta Suzuki, Shoji Yamamoto, Hizuru Nakajima
article en
1 citations

Abstract

Abstract Human activities have significantly increased carbon dioxide emissions, leading to global warming and ocean acidification, which threaten marine ecosystems, including coral reefs with high biodiversity. Coral reef maintenance relies on a balance between calcium carbonate formation and dissolution. Among the processes, sandy sediments, covering vast areas and highly sensitive to ocean acidification, require urgent investigations to elucidate their dissolution mechanisms. However, conventional glass electrodes have limitations in continuous monitoring of the spatiotemporal distribution of pH within sediment. To address this, we developed a multichannel ion‐sensitive field‐effect transistor (ISFET)‐pH sensor array with a tantalum oxide sensing membrane, which was embedded in the sediment to enable high‐resolution and continuous pH monitoring. A 24‐h pH monitoring experiment was conducted in coral reef sediments to validate the method. The performance of the sensor was evaluated through both laboratory and field observations, and a comparison with a conventional glass electrode confirmed that the ISFET‐pH sensor provided stable pH measurements within the uncertainty range of the glass electrode. The developed sensor array is a low‐cost and durable automatic measurement system, offering an alternative to conventional glass electrodes, which are expensive and fragile. However, optimizing sputtering conditions, annealing processes, and data processing techniques is necessary to reduce environmental influences and enhance measurement accuracy. The proposed array‐based observation method enables the acquisition of high‐resolution vertical pH profiles and is expected to contribute to the quantitative evaluation of the chemical role of sandy sediments and the elucidation of carbon cycling in coral reef ecosystems.

Limnology and Oceanography MethodsVol. 23(9)
Tokyo University of Pharmacy and Life Sciences (JP), Nagano Prefectural College (JP), Engineering Advancement Association of Japan (JP), Tokyo Metropolitan University (JP), The University of Tokyo (JP)
University of the Ryukyus, Tokyo Metropolitan University, Japan Society for the Promotion of Science
Life below water
Openalex Percentile: Top 15%
Ocean Acidification Effects and Responses
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.