Application value of serum miR-363 combined with arterial blood gas analysis parameters and lung ultrasound score in neonatal respiratory distress syndrome

Neonatal respiratory distress syndrome (NRDS) is caused by a deficiency of alveolar surface-active substances. The aim of this study was to investigate the value of miR-363 combined with arterial blood gas analysis parameters and lung ultrasound (LUS) score for diagnosis and prognostic assessment in NRDS. In this study, 104 neonates with NRDS and 76 healthy were included as subjects. RT-qPCR was used to detect the serum miR-363 expression. Neonatal artery blood was collected for arterial blood gas analysis and LUS score was performed on neonates. ROC curves were performed to analyze the diagnostic and prognostic predictive efficacy of single and combined indicators. Independent risk factors for development of NRDS and poor prognosis in neonates were analyzed by logistic analysis. Association of miR-363 with analysis indicators was assessed by Pearson correlation analysis. miR-363 expression was significantly lower in NRDS neonates than in healthy newborns. Compared to the healthy group, NRDS neonates had lower pH, PaO2, HCO3-, and BE levels, and higher PaCO2 levels and LUS scores, and the same trend was observed for the tests in the poor prognosis group. ROC curves indicated that the diagnostic efficacy of combined indicators was higher than that of single indicators. Logistic analysis showed that miR-363 was a risk factor for the development and poor prognosis of NRDS. Pearson correlation analysis suggested that miR-363 was positively correlated with pH, PaO2, HCO3-, and BE levels, and negatively correlated with PaCO2 levels and LUS scores. Serum miR-363 in combination with arterial blood gas analysis parameters and LUS scores may serve as a tool for diagnostic and prognostic risk assessment of NRDS, providing guidance for optimizing clinical strategies.

Authors

Institutions

Publication Details

Journal
Annales de biologie clinique
Published
2025-08-01
DOI
https://doi.org/10.1684/abc.2025.1985
Primary Topic
Ultrasound in Clinical Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application value of serum miR-363 combined with arterial blood gas analysis parameters and lung ultrasound score in neonatal respiratory distress syndrome

Yanan Hou, Jing Mo, L. Chen, Zhihua Liu et al.
Annales de biologie clinique
Ultrasound in Clinical Applications
article

Application value of serum miR-363 combined with arterial blood gas analysis parameters and lung ultrasound score in neonatal respiratory distress syndrome

Yanan Hou, Jing Mo, L. Chen, Zhihua Liu, Zhiqiang Liu, Yang Zhang
article en

Abstract

Neonatal respiratory distress syndrome (NRDS) is caused by a deficiency of alveolar surface-active substances. The aim of this study was to investigate the value of miR-363 combined with arterial blood gas analysis parameters and lung ultrasound (LUS) score for diagnosis and prognostic assessment in NRDS. In this study, 104 neonates with NRDS and 76 healthy were included as subjects. RT-qPCR was used to detect the serum miR-363 expression. Neonatal artery blood was collected for arterial blood gas analysis and LUS score was performed on neonates. ROC curves were performed to analyze the diagnostic and prognostic predictive efficacy of single and combined indicators. Independent risk factors for development of NRDS and poor prognosis in neonates were analyzed by logistic analysis. Association of miR-363 with analysis indicators was assessed by Pearson correlation analysis. miR-363 expression was significantly lower in NRDS neonates than in healthy newborns. Compared to the healthy group, NRDS neonates had lower pH, PaO2, HCO3-, and BE levels, and higher PaCO2 levels and LUS scores, and the same trend was observed for the tests in the poor prognosis group. ROC curves indicated that the diagnostic efficacy of combined indicators was higher than that of single indicators. Logistic analysis showed that miR-363 was a risk factor for the development and poor prognosis of NRDS. Pearson correlation analysis suggested that miR-363 was positively correlated with pH, PaO2, HCO3-, and BE levels, and negatively correlated with PaCO2 levels and LUS scores. Serum miR-363 in combination with arterial blood gas analysis parameters and LUS scores may serve as a tool for diagnostic and prognostic risk assessment of NRDS, providing guidance for optimizing clinical strategies.

Annales de biologie cliniqueVol. 83(4)
Shengli Oilfield Central Hospital (CN)
No poverty
Openalex Percentile: Top 77%
Ultrasound in Clinical Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.