Improper arterial catheter blood sampling method affects hemoglobin test results: A cautionary tale

Arterial catheter blood sampling is widely used among critically ill patients to minimize repeated punctures; however, improper techniques may lead to misleading laboratory results. This case report presents a clinically significant hemoglobin discrepancy observed between blood gas analyzer and automated hematology analyzer during arterial catheter sampling in a patient with cerebral infarction. After catheter placement, the interplatform hemoglobin discrepancy reached 13 g/L despite prior concordance. The discordance was attributed to pre-analytical errors, including inadequate discard volume (4-5 mL) of heparinized saline-contaminated blood, which causes sample dilution. This case underscores that catheter sampling protocols must rigorously focus on dead space clearance to prevent artifactual hemoglobin variations. Such vigilance is particularly critical in hemodynamically unstable patients, in whom erroneous values may directly impact transfusion decisions. Adherence to evidence-based discard volume guidelines, with protocol tailoring based on individual patient factors, constitutes an essential safeguard for test accuracy in critical care settings.

Authors

Institutions

Publication Details

Journal
Journal of International Medical Research
Published
2025-08-01
DOI
https://doi.org/10.1177/03000605251363520
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improper arterial catheter blood sampling method affects hemoglobin test results: A cautionary tale

Jinle Wang, Lei Zhang, Qingqing Bi, Kegang Tian et al.
Journal of International Medical Research
Hemodynamic Monitoring and Therapy
article

Improper arterial catheter blood sampling method affects hemoglobin test results: A cautionary tale

Jinle Wang, Lei Zhang, Qingqing Bi, Kegang Tian, Xiaofeng Mu, Huihui Jiang
article en

Abstract

Arterial catheter blood sampling is widely used among critically ill patients to minimize repeated punctures; however, improper techniques may lead to misleading laboratory results. This case report presents a clinically significant hemoglobin discrepancy observed between blood gas analyzer and automated hematology analyzer during arterial catheter sampling in a patient with cerebral infarction. After catheter placement, the interplatform hemoglobin discrepancy reached 13 g/L despite prior concordance. The discordance was attributed to pre-analytical errors, including inadequate discard volume (4-5 mL) of heparinized saline-contaminated blood, which causes sample dilution. This case underscores that catheter sampling protocols must rigorously focus on dead space clearance to prevent artifactual hemoglobin variations. Such vigilance is particularly critical in hemodynamically unstable patients, in whom erroneous values may directly impact transfusion decisions. Adherence to evidence-based discard volume guidelines, with protocol tailoring based on individual patient factors, constitutes an essential safeguard for test accuracy in critical care settings.

Journal of International Medical ResearchVol. 53(8)
Qingdao University (CN), Affiliated Hospital of Qingdao University (CN)
Good health and well-being
Openalex Percentile: Top 67%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improper arterial catheter blood sampling method affects hemoglobin test results: A cautionary tale — Jinle Wang, Lei Zhang, et al. · Journal of International Medical Research (2025) | TGRS Research Map | TGRS