Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response

Abstract Extremely low‐frequency (below 10 Hz) current‐induced magnetic field detection has significant applications in high‐voltage DC systems, lithium‐ion battery diagnostics, and industrial process monitoring. Nitrogen‐vacancy (NV) ensembles magnetometry typically employs flux concentrators to enhance magnetic detection sensitivity, but this enhancement comes at the cost of introducing more low‐frequency magnetic noise, such as the thermal magnetization noise of ferromagnetic materials, directly limiting their potential at low frequencies. Here, the enhancement of the signal‐to‐noise ratio (SNR) in extremely low‐frequency magnetic field detection within NV magnetometry, achieved via nonlinear response, is experimentally demonstrated. The approach enables the extension of the magnetic field detection bandwidth to the Hz range while simultaneously enhancing magnetic field sensitivity by using a magnetic flux concentrator. The magnetic field from the coil current, enhanced by the flux concentrator, drives NV ensembles into the nonlinear response region of the differential spectrum of the optically detected magnetic resonance (ODMR). Within this regime, nonlinear effects generate signal‐frequency mixing and 1/f noise suppression. By pre‐modulating the target signal at the driving frequency, its recovery through frequency mixing retains 1/f noise suppression, consequently enhancing SNR. For the 0.5 Hz signal, experimental results demonstrate up to a 2.6‐fold enhancement in SNR. This approach offers a new strategy for utilizing NV ensembles in extremely low‐frequency magnetic field detection.

Authors

Institutions

Publication Details

Journal
Advanced Optical Materials
Published
2025-08-05
DOI
https://doi.org/10.1002/adom.202501340
Citations
1
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response

Renfei Zheng, Jingwei Fan, Kong Zhen, Jianpei Geng et al.
1 citations
Advanced Optical Materials
Diamond and Carbon-based Materials Research
0.52
article

Enhancing Extremely Low‐Frequency Signal‐to‐Noise Ratio of Diamond Magnetometry via Nonlinear Response

Renfei Zheng, Jingwei Fan, Kong Zhen, Jianpei Geng, Zhifei Yu, Bing Chen, Jiayu Xu, Chunlong Li, Hao Wu, Fei Xue
article en
1 citations

Abstract

Abstract Extremely low‐frequency (below 10 Hz) current‐induced magnetic field detection has significant applications in high‐voltage DC systems, lithium‐ion battery diagnostics, and industrial process monitoring. Nitrogen‐vacancy (NV) ensembles magnetometry typically employs flux concentrators to enhance magnetic detection sensitivity, but this enhancement comes at the cost of introducing more low‐frequency magnetic noise, such as the thermal magnetization noise of ferromagnetic materials, directly limiting their potential at low frequencies. Here, the enhancement of the signal‐to‐noise ratio (SNR) in extremely low‐frequency magnetic field detection within NV magnetometry, achieved via nonlinear response, is experimentally demonstrated. The approach enables the extension of the magnetic field detection bandwidth to the Hz range while simultaneously enhancing magnetic field sensitivity by using a magnetic flux concentrator. The magnetic field from the coil current, enhanced by the flux concentrator, drives NV ensembles into the nonlinear response region of the differential spectrum of the optically detected magnetic resonance (ODMR). Within this regime, nonlinear effects generate signal‐frequency mixing and 1/f noise suppression. By pre‐modulating the target signal at the driving frequency, its recovery through frequency mixing retains 1/f noise suppression, consequently enhancing SNR. For the 0.5 Hz signal, experimental results demonstrate up to a 2.6‐fold enhancement in SNR. This approach offers a new strategy for utilizing NV ensembles in extremely low‐frequency magnetic field detection.

Advanced Optical MaterialsVol. 13(26)
Hefei University of Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, National Key Research and Development Program of China, Fundamental Research Funds for the Central Universities
Openalex Percentile: Top 35%
Diamond and Carbon-based Materials Research
0.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.