Two-Dimensional Reproducing Kernel-Based Interpolation Approximation for Best Regularization Parameter in Electrical Tomography Algorithm

The regularization parameter plays an important role in regularization-based electrical tomography (ET) algorithms, but the existing methods generally cannot determine the parameter. Moreover, these methods are not real-time since a thorough search must be performed for the best parameter. To address the issue, a reproducing kernel-based interpolation approximation method is proposed to efficiently estimate the best regularization parameter from a group of representative samples. The optimization and generation of the new method have been verified by theoretical analysis and experimental demonstration. The theoretical evaluation is conducted in a Hilbert space with a known reproducing kernel, and its symmetry ensures the uniqueness of the interpolation. And experimental validation is carried out using both simulated and actual models, each with a range of distinct features. Results indicate that the new method can approximately find the best regularization parameter. Consequently, when using the regularization parameter, the new method can effectively improve both the spatial resolution and steadiness of ET imaging process.

Authors

Institutions

Publication Details

Journal
Symmetry
Published
2025-08-05
DOI
https://doi.org/10.3390/sym17081242
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-Dimensional Reproducing Kernel-Based Interpolation Approximation for Best Regularization Parameter in Electrical Tomography Algorithm

Shihong Yue, Fanpeng Dong
Symmetry
Electrical and Bioimpedance Tomography
article

Two-Dimensional Reproducing Kernel-Based Interpolation Approximation for Best Regularization Parameter in Electrical Tomography Algorithm

Shihong Yue, Fanpeng Dong
article en

Abstract

The regularization parameter plays an important role in regularization-based electrical tomography (ET) algorithms, but the existing methods generally cannot determine the parameter. Moreover, these methods are not real-time since a thorough search must be performed for the best parameter. To address the issue, a reproducing kernel-based interpolation approximation method is proposed to efficiently estimate the best regularization parameter from a group of representative samples. The optimization and generation of the new method have been verified by theoretical analysis and experimental demonstration. The theoretical evaluation is conducted in a Hilbert space with a known reproducing kernel, and its symmetry ensures the uniqueness of the interpolation. And experimental validation is carried out using both simulated and actual models, each with a range of distinct features. Results indicate that the new method can approximately find the best regularization parameter. Consequently, when using the regularization parameter, the new method can effectively improve both the spatial resolution and steadiness of ET imaging process.

SymmetryVol. 17(8)
Tianjin University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 82%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Two-Dimensional Reproducing Kernel-Based Interpolation Approximation for Best Regularization Parameter in Electrical Tomography Algorithm — Shihong Yue, Fanpeng Dong · Symmetry (2025) | TGRS Research Map | TGRS