A Microneedle-Based Electrochemical Sensor with Multiplex Detection in Physiological Environment and Incorporated in a Portable Device

The number of disorders linked to deficiencies in vital ions, such as calcium (Ca<sup>2+</sup>) and potassium (K<sup>+</sup>), has dramatically increased in recent years. Numerous research studies have proposed the development of a sensor for early detection; however, the bulk of these investigations include the time-consuming process of drawing blood samples for testing. To overcome these challenges, this research highlights the development of a novel portable microneedle-based device for the multiplexed detection of Ca<sup>2+</sup> and K<sup>+</sup>, as well as pH, in artificial interstitial fluid (ISF). A passivation layer of ArCare was investigated to improve the stability, reliability, and repeatability of the microneedle sensors, enhancing their sensitivity and accuracy. Microneedle sensors were modified with Poly-(3,4-ethylenedioxythiophene) (PEDOT) and an ion-selective membrane (ISM) to reduce interference caused by other ions when tested in complex media. Successful modification of the surface with PEDOT and ISM was confirmed using electrochemical characterization, Raman Spectroscopy, and Scanning Electron Microscopy (SEM) analysis. The results demonstrated a linear response in the detection of both Ca<sup>2+</sup>and K<sup>+</sup> ions with respect to concentration, with a high coefficient of determination (<i>r</i> <sup>2</sup> >0.9) indicating strong reliability. Additionally, tests were carried out to study the effect of pH on the detection of Ca<sup>2+</sup> and K<sup>+</sup>, revealing a linear detection for both ions across varying pH levels. The multiparametric detection of pH and Ca<sup>2+</sup> or K<sup>+</sup> was carried out using an in-house built smart sensing platform known as Portable Unit Lab-on-Site Electrochemistry (PULSE). Overall, this work highlights the potential of multi-ion microneedle sensors in portable real-time health monitoring applications.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2025-08-05
DOI
https://doi.org/10.1021/acsomega.5c04024
Citations
3
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
2.21

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Microneedle-Based Electrochemical Sensor with Multiplex Detection in Physiological Environment and Incorporated in a Portable Device

Fiona Barry, Cláudia Ferreira, Paul Galvin, Eoin O’Keeffe et al.
3 citations
ACS Omega
Analytical Chemistry and Sensors
2.21
article

A Microneedle-Based Electrochemical Sensor with Multiplex Detection in Physiological Environment and Incorporated in a Portable Device

Fiona Barry, Cláudia Ferreira, Paul Galvin, Eoin O’Keeffe, Sofia Rodrigues Teixeira, Chinmay Thatte, Valeria Cioce
article en
3 citations

Abstract

The number of disorders linked to deficiencies in vital ions, such as calcium (Ca<sup>2+</sup>) and potassium (K<sup>+</sup>), has dramatically increased in recent years. Numerous research studies have proposed the development of a sensor for early detection; however, the bulk of these investigations include the time-consuming process of drawing blood samples for testing. To overcome these challenges, this research highlights the development of a novel portable microneedle-based device for the multiplexed detection of Ca<sup>2+</sup> and K<sup>+</sup>, as well as pH, in artificial interstitial fluid (ISF). A passivation layer of ArCare was investigated to improve the stability, reliability, and repeatability of the microneedle sensors, enhancing their sensitivity and accuracy. Microneedle sensors were modified with Poly-(3,4-ethylenedioxythiophene) (PEDOT) and an ion-selective membrane (ISM) to reduce interference caused by other ions when tested in complex media. Successful modification of the surface with PEDOT and ISM was confirmed using electrochemical characterization, Raman Spectroscopy, and Scanning Electron Microscopy (SEM) analysis. The results demonstrated a linear response in the detection of both Ca<sup>2+</sup>and K<sup>+</sup> ions with respect to concentration, with a high coefficient of determination (<i>r</i> <sup>2</sup> >0.9) indicating strong reliability. Additionally, tests were carried out to study the effect of pH on the detection of Ca<sup>2+</sup> and K<sup>+</sup>, revealing a linear detection for both ions across varying pH levels. The multiparametric detection of pH and Ca<sup>2+</sup> or K<sup>+</sup> was carried out using an in-house built smart sensing platform known as Portable Unit Lab-on-Site Electrochemistry (PULSE). Overall, this work highlights the potential of multi-ion microneedle sensors in portable real-time health monitoring applications.

ACS OmegaVol. 10(32)
Politecnico di Torino (IT), Munster Technological University (IE), International Energy Research Centre (IE)
Department of Agriculture, Food and the Marine, Ireland, Science Foundation Ireland, European Regional Development Fund
Openalex Percentile: Top 11%
Analytical Chemistry and Sensors
2.21
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.