Electrocatalytic determination of homocysteine using a bimetallic Zn-Ni MOF nanosheets/graphene oxide nanocomposite/ferrocene dicarboxylic acid/ionic liquid modified carbon paste electrode

We synthesized the bimetallic zinc-nickel metal-organic framework nanosheets/graphene oxide nanocomposite (Zn-Ni MOF NSs/GO nanocomposite) through a solvo/hydrothermal method. We characterized it utilizing X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), and energy dispersive X-ray spectroscopy (EDX). Then, a modified carbon paste electrode with the Zn-Ni-MOF NSs/GO nanocomposite, ionic liquid (IL), and ferrocene dicarboxylic acid (FCD) was prepared (Zn-Ni MOF NSs/GO/IL/FCD/CPE) for the voltammetric determination of homocysteine (Hcys). The electrocatalytic performance of the Zn-Ni MOF NSs/GO/IL/FCD/CPE sensor toward Hcys was studied <i>via</i> various voltammetric methods (cyclic voltammetry (CV), differential pulse voltammetry (DPV)) and chronoamperometry. The results of the CV tests demonstrated that the Zn-Ni MOF NSs/GO/IL/FCD/CPE sensor exhibited superior catalytic performance for the oxidation of Hcys within a phosphate buffer solution (PBS, pH of 7.0) compared to other electrodes. This enhanced activity can be attributed to the combined effects of the IL, FCD, and the Zn-Ni-MOF NSs/GO nanocomposite. The designed electrode was utilized to determine Hcys using DPV. Under optimized conditions and parameters, the anodic current response varied linearly with Hcys levels in the ranges of 0.05 to 12.5 and 12.5 to 200.0 μM, achieving a sensitivity of 0.6408 μA μM<sup>-1</sup>. With this approach, the limit of detection (LOD) was determined to be 0.02 μM. Moreover, the created sensor exhibited good reproducibility, repeatability, and stability. Validation in real samples demonstrated the sensor's practical utility for Hcys detection, yielding excellent recovery rates between 98% and 104.3%. This developed electrochemical sensor shows considerable potential for clinical applications in the detection of Hcys.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00759c
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrocatalytic determination of homocysteine using a bimetallic Zn-Ni MOF nanosheets/graphene oxide nanocomposite/ferrocene dicarboxylic acid/ionic liquid modified carbon paste electrode

Fatemeh Aziz‐Aliabadi, Somayeh Tajik, Sayed Zia Mohammadi, Hadi Beitollahi et al.
Analytical Methods
Electrochemical sensors and biosensors
article

Electrocatalytic determination of homocysteine using a bimetallic Zn-Ni MOF nanosheets/graphene oxide nanocomposite/ferrocene dicarboxylic acid/ionic liquid modified carbon paste electrode

Fatemeh Aziz‐Aliabadi, Somayeh Tajik, Sayed Zia Mohammadi, Hadi Beitollahi, Mohammad Reza Aflatoonian, S Karimi Afshar
article en

Abstract

We synthesized the bimetallic zinc-nickel metal-organic framework nanosheets/graphene oxide nanocomposite (Zn-Ni MOF NSs/GO nanocomposite) through a solvo/hydrothermal method. We characterized it utilizing X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM), and energy dispersive X-ray spectroscopy (EDX). Then, a modified carbon paste electrode with the Zn-Ni-MOF NSs/GO nanocomposite, ionic liquid (IL), and ferrocene dicarboxylic acid (FCD) was prepared (Zn-Ni MOF NSs/GO/IL/FCD/CPE) for the voltammetric determination of homocysteine (Hcys). The electrocatalytic performance of the Zn-Ni MOF NSs/GO/IL/FCD/CPE sensor toward Hcys was studied <i>via</i> various voltammetric methods (cyclic voltammetry (CV), differential pulse voltammetry (DPV)) and chronoamperometry. The results of the CV tests demonstrated that the Zn-Ni MOF NSs/GO/IL/FCD/CPE sensor exhibited superior catalytic performance for the oxidation of Hcys within a phosphate buffer solution (PBS, pH of 7.0) compared to other electrodes. This enhanced activity can be attributed to the combined effects of the IL, FCD, and the Zn-Ni-MOF NSs/GO nanocomposite. The designed electrode was utilized to determine Hcys using DPV. Under optimized conditions and parameters, the anodic current response varied linearly with Hcys levels in the ranges of 0.05 to 12.5 and 12.5 to 200.0 μM, achieving a sensitivity of 0.6408 μA μM<sup>-1</sup>. With this approach, the limit of detection (LOD) was determined to be 0.02 μM. Moreover, the created sensor exhibited good reproducibility, repeatability, and stability. Validation in real samples demonstrated the sensor's practical utility for Hcys detection, yielding excellent recovery rates between 98% and 104.3%. This developed electrochemical sensor shows considerable potential for clinical applications in the detection of Hcys.

Analytical MethodsVol. 17(32)
Graduate University of Advanced Technology (IR), Kerman University of Medical Sciences (IR), Payame Noor University (IR)
National Institute for Medical Research Development
Openalex Percentile: Top 82%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.