A risk-averse optimal dispatch scheme for data centers considering carbon emission and water constraints based on enhanced ADMM

• Proposes a novel water footprint model integrating temperature effects and tiered pricing for precise DC water consumption evaluation. • Develops a CVaR-based risk-averse scheme managing workload, PV, and temperature uncertainties to reduce extreme-scenario losses. • Enhances ADMM with step-size control to accelerate convergence while maintaining optimality gap in distributed DC dispatch. • Addresses spatio-temporal challenges by incorporating time-difference effects in large-scale networks and water-carbon constraints for eco-economic efficiency. • Validates water reduction under penalty pricing via workload shifting, balancing operational costs and environmental sustainability. With the background of global climate change, the significance of energy utilization considering environmentally friendly is widely recognized. As a heavy load user in the power system, the role of data center (DC) in environment protection needs to be considered in the operation of the power system. This paper proposes a distributed risk-averse optimal dispatch scheme for DCs considering carbon emission and water restriction. Firstly, a model for the consumption of cooling water was established based on the equation of heat conduction, and the utilization of water resources in data centers was restricted by imposing an excess penalty price; Furthermore, the conditional value at risk (CVaR) method is introduced to manage the risks arising from diverse uncertainties, including workload, power of photovoltaic and temperature in the proposed scheme. To improve computational performance and protect the privacy between the DCs, the improved multiplier based alternating direction method of multipliers (M−ADMM) distributed solution method is developed to solve the dispatch model for DCs, and consider the time difference between photovoltaics and temperature caused by geographical longitude location. Numerical results illustrate the benefits for environment protection and economic, risk management ability, and computational performance of the proposed scheme.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2025-08-05
DOI
https://doi.org/10.1016/j.ijepes.2025.110976
Citations
3
Primary Topic
Smart Grid Energy Management
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A risk-averse optimal dispatch scheme for data centers considering carbon emission and water constraints based on enhanced ADMM

Shengyi Wang, Bo Zeng, Jiayu Wang, Chen Liang et al.
3 citations
International Journal of Electrical Power & Energy Systems
Smart Grid Energy Management
2.19
article

A risk-averse optimal dispatch scheme for data centers considering carbon emission and water constraints based on enhanced ADMM

Shengyi Wang, Bo Zeng, Jiayu Wang, Chen Liang, Jiayi Zhang, Haotian Ma
article en
3 citations

Abstract

• Proposes a novel water footprint model integrating temperature effects and tiered pricing for precise DC water consumption evaluation. • Develops a CVaR-based risk-averse scheme managing workload, PV, and temperature uncertainties to reduce extreme-scenario losses. • Enhances ADMM with step-size control to accelerate convergence while maintaining optimality gap in distributed DC dispatch. • Addresses spatio-temporal challenges by incorporating time-difference effects in large-scale networks and water-carbon constraints for eco-economic efficiency. • Validates water reduction under penalty pricing via workload shifting, balancing operational costs and environmental sustainability. With the background of global climate change, the significance of energy utilization considering environmentally friendly is widely recognized. As a heavy load user in the power system, the role of data center (DC) in environment protection needs to be considered in the operation of the power system. This paper proposes a distributed risk-averse optimal dispatch scheme for DCs considering carbon emission and water restriction. Firstly, a model for the consumption of cooling water was established based on the equation of heat conduction, and the utilization of water resources in data centers was restricted by imposing an excess penalty price; Furthermore, the conditional value at risk (CVaR) method is introduced to manage the risks arising from diverse uncertainties, including workload, power of photovoltaic and temperature in the proposed scheme. To improve computational performance and protect the privacy between the DCs, the improved multiplier based alternating direction method of multipliers (M−ADMM) distributed solution method is developed to solve the dispatch model for DCs, and consider the time difference between photovoltaics and temperature caused by geographical longitude location. Numerical results illustrate the benefits for environment protection and economic, risk management ability, and computational performance of the proposed scheme.

International Journal of Electrical Power & Energy SystemsVol. 171
North China Electric Power University (CN)
National Natural Science Foundation of China, Beijing Nova Program
Openalex Percentile: Top 11%
Smart Grid Energy Management
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.