Progressive Loosening in Metal-on-Metal Total Hip Arthroplasty after Fifteen Years of Effective Function: Two Case Reports
Metallosis poses a significant risk in MoM THA, caused by wear and corrosion, leading to systemic and local tissue damage. Timely diagnosis through clinical evaluation, imaging, and serum metal ion levels is critical for intervention. Revision surgeries are effective in managing metallosis and restoring function. These cases highlight the importance of long-term monitoring and the consideration of alternative bearing surfaces in hip arthroplasty.
Authors
- Jai Thilak
- Ganesh Prasad
- Mohammad Salil
Institutions
- Amrita Institute of Medical Sciences and Research Centre (IN)
Publication Details
- Journal
- Journal of Orthopaedic Case Reports
- Published
- 2025-01-01
- DOI
- https://doi.org/10.13107/jocr.2025.v15.i08.5890
- Primary Topic
- Orthopaedic implants and arthroplasty
- Type
- article
- Field-Weighted Citation Impact
- 0.00