Autism EEG Signal Pre-Processing: Performance Evaluation of MS-ICA and Butterworth Filter

Autism Spectrum Disorder (ASD) is a neurological condition characterized by challenges in communication and social interaction, accompanied by the development of repetitive behavioral patterns. Electroencephalography (EEG) is primarily used to assess brain function in children with Autism Spectrum Disorder (ASD), mainly due to its non-invasive nature and superior temporal resolution compared to other neuroimaging methods. However, EEG signals are often contaminated by biological artifacts, such as eye movements and muscle contractions, which can significantly distort analysis outcomes. Pre-processing is therefore required to increase the accuracy of the EEG signal before additional analysis. The goal of this study was to compare and evaluate the performance of two pre-processing techniques, the Butterworth Band-Pass Filter and Multiscale Independent Component Analysis (MS-ICA), using four different performance metrics: Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), and Signal-to-Noise Ratio (SNR). The Butterworth method has an MAE of 227.57, which is acceptable. However, it produced an MSE of 160,653.22, an RMSE of 394.49, and a maximum SNR of only 1.33 dB. MS-ICA performs far better with a best MAE of only 0.44, an MSE of 3.33, an RMSE of 1.76, and an SNR of 30.88 dB. Paired t-test (p < 0.05) was employed to determine statistical significance, while Cohen's d was used to assess the practical significance of the results. The effect sizes of MAE (d = 1.60), MSE (d = 1.02), RMSE (d = 1.54), and SNR (d = -9.50) were all calculated as large. These findings demonstrate that MS-ICA offers both statistical advantages and strong practical usefulness for noise removal while preserving the structural integrity of the original EEG signals. Therefore, MS-ICA proves to be the best approach for pre-processing EEG signals to be used for analysis in children with ASD

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
Published
2025-08-05
DOI
https://doi.org/10.35882/ijeeemi.v7i3.107
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Autism EEG Signal Pre-Processing: Performance Evaluation of MS-ICA and Butterworth Filter

Muhammad Irhamsyah, Yudha Nurdin, Yuwaldi Away, Melinda Melinda et al.
Indonesian Journal of Electronics Electromedical Engineering and Medical Informatics
EEG and Brain-Computer Interfaces
article

Autism EEG Signal Pre-Processing: Performance Evaluation of MS-ICA and Butterworth Filter

Muhammad Irhamsyah, Yudha Nurdin, Yuwaldi Away, Melinda Melinda, W. K. Wong, Muhammad Rahmat
article en

Abstract

Autism Spectrum Disorder (ASD) is a neurological condition characterized by challenges in communication and social interaction, accompanied by the development of repetitive behavioral patterns. Electroencephalography (EEG) is primarily used to assess brain function in children with Autism Spectrum Disorder (ASD), mainly due to its non-invasive nature and superior temporal resolution compared to other neuroimaging methods. However, EEG signals are often contaminated by biological artifacts, such as eye movements and muscle contractions, which can significantly distort analysis outcomes. Pre-processing is therefore required to increase the accuracy of the EEG signal before additional analysis. The goal of this study was to compare and evaluate the performance of two pre-processing techniques, the Butterworth Band-Pass Filter and Multiscale Independent Component Analysis (MS-ICA), using four different performance metrics: Mean Absolute Error (MAE), Mean Squared Error (MSE), Root Mean Squared Error (RMSE), and Signal-to-Noise Ratio (SNR). The Butterworth method has an MAE of 227.57, which is acceptable. However, it produced an MSE of 160,653.22, an RMSE of 394.49, and a maximum SNR of only 1.33 dB. MS-ICA performs far better with a best MAE of only 0.44, an MSE of 3.33, an RMSE of 1.76, and an SNR of 30.88 dB. Paired t-test (p < 0.05) was employed to determine statistical significance, while Cohen's d was used to assess the practical significance of the results. The effect sizes of MAE (d = 1.60), MSE (d = 1.02), RMSE (d = 1.54), and SNR (d = -9.50) were all calculated as large. These findings demonstrate that MS-ICA offers both statistical advantages and strong practical usefulness for noise removal while preserving the structural integrity of the original EEG signals. Therefore, MS-ICA proves to be the best approach for pre-processing EEG signals to be used for analysis in children with ASD

Indonesian Journal of Electronics Electromedical Engineering and Medical InformaticsVol. 7(3)
Curtin University Sarawak (MY), Universitas Syiah Kuala (ID)
Reduced inequalities
Openalex Percentile: Top 81%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.