Evaluation of component alignment in total knee arthroplasty using patient-specific instrumentation versus conventional guides: a retrospective study
Preoperative measurements and demographics were similar among the two groups. No statistically significant differences were found between postoperative radiographic findings in patients operated on with PSI or CI. A restoration of the femorotibial axis was achieved in 87.8% and 87.0% of patients treated with PSI and CI, respectively (p = 0.583). Coronal alignment of the femoral component was within acceptable limits in 97.6% and 94.4% (p = 0.631) of patients of the PSI and CI groups, respectively. The respective percentages for the tibial component were 85.3% and 83.3% (p = 0.510) of patients. An accurate coronal plane radiological outcome was achieved in 82.9% and 77.8% of patients treated with PSI and CI, respectively (p = 0.611) Conclusions: The use of PSI does not increase the accuracy of component positioning and leg axis restoration compared to CI in TKA in patients with mild deformity.
Authors
- Georgios Renieris (ORCID: https://orcid.org/0000-0002-2985-0901)
- Eleni Georgaki
- Natalia Renieri
- Athanasios Georgokostas
Institutions
- Athens Medical Center (GR)
- Hippocration General Hospital (GR)
Publication Details
- Journal
- SICOT-J
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1051/sicotj/2025044
- Primary Topic
- Total Knee Arthroplasty Outcomes
- Type
- article
- Field-Weighted Citation Impact
- 0.00