Central Venous Pressure Catheter Malposition from Right Internal Jugular Vein into the contralateral innominate vein: A Rare complication

CVCs are inserted for many different indications in cardiac surgery and ICU. These include administering drugs (anaesthetic and vasoactive agents, antibiotics, chemotherapy), monitoring central venous pressure (CVP)or hemodynamic monitoring, measurement of central venous oxygen saturation (SCVO2), renal replacement therapy, total parenteral nutrition, poor peripheral venous access, cardiac catheterization, and transvenous cardiac pacing. Despite the level of skill of the operator and the use of ultrasound guidance, CVC placement can result in CVC malposition. Easy and uncomplicated catheterisation, free aspiration of blood and monitoring of catheterisation do not guarantee correct placement of the IJV catheter. Though, placement of a catheter through the RIJV is associated with the lowest incidence of malposition. Ultrasound, ECG guidance, real-time X-ray imaging, surgical confirmation either by palpation in SVC or visualized in the RA, and saline injection test are definite confirmation and dramatically increase the successful placement of needles, guidewires, and catheters, but significant numbers of catheter misplacements can still occur, particularly if operators are not fully proficient in such techniques. A case of RIJV inserted CVP catheter malposition has been reported in 57 years old, 61 kg and 155cm height with short and thick neck patient presented with triple vessel CAD posted for OP-CABG surgery. Postoperative Chest X-Ray revealed a right sided CVP line catheter malposition in the contralateral innominate vein. Even though, the malposition of the CVP catheter inserted via RIJV is less frequently reported.

Authors

Publication Details

Journal
American Journal of Medical and Clinical Research & Reviews
Published
2025-01-01
DOI
https://doi.org/10.58372/2835-6276.1321
Primary Topic
Central Venous Catheters and Hemodialysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Central Venous Pressure Catheter Malposition from Right Internal Jugular Vein into the contralateral innominate vein: A Rare complication

Divya Goel, Rashmi Sharma, Deepak Agarwal, Bhavna Chawla et al.
American Journal of Medical and Clinical Research & Reviews
Central Venous Catheters and Hemodialysis
article

Central Venous Pressure Catheter Malposition from Right Internal Jugular Vein into the contralateral innominate vein: A Rare complication

Divya Goel, Rashmi Sharma, Deepak Agarwal, Bhavna Chawla, Abhinav Arun Sonkar, Sadhna Sharma, Dr.Vishnu Datt
article en

Abstract

CVCs are inserted for many different indications in cardiac surgery and ICU. These include administering drugs (anaesthetic and vasoactive agents, antibiotics, chemotherapy), monitoring central venous pressure (CVP)or hemodynamic monitoring, measurement of central venous oxygen saturation (SCVO2), renal replacement therapy, total parenteral nutrition, poor peripheral venous access, cardiac catheterization, and transvenous cardiac pacing. Despite the level of skill of the operator and the use of ultrasound guidance, CVC placement can result in CVC malposition. Easy and uncomplicated catheterisation, free aspiration of blood and monitoring of catheterisation do not guarantee correct placement of the IJV catheter. Though, placement of a catheter through the RIJV is associated with the lowest incidence of malposition. Ultrasound, ECG guidance, real-time X-ray imaging, surgical confirmation either by palpation in SVC or visualized in the RA, and saline injection test are definite confirmation and dramatically increase the successful placement of needles, guidewires, and catheters, but significant numbers of catheter misplacements can still occur, particularly if operators are not fully proficient in such techniques. A case of RIJV inserted CVP catheter malposition has been reported in 57 years old, 61 kg and 155cm height with short and thick neck patient presented with triple vessel CAD posted for OP-CABG surgery. Postoperative Chest X-Ray revealed a right sided CVP line catheter malposition in the contralateral innominate vein. Even though, the malposition of the CVP catheter inserted via RIJV is less frequently reported.

American Journal of Medical and Clinical Research & ReviewsVol. 04(07)
Openalex Percentile: Top 69%
Central Venous Catheters and Hemodialysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.