<scp>3D</scp> printed nerve guidance conduit for biologics‐free nerve regeneration and vascular integration

There is a clinical need for an effective nerve guidance conduit to treat peripheral nerve injuries. Many studies have explored different materials and active cues to guide neural regeneration, with some success. However, none have demonstrated a comparable or better functional recovery than the clinical standard autograft. Autografts are often insufficient for reconstruction of an injury to long nerves such as the sciatic or brachial plexus. Synthetic nerve guidance conduits (NGCs) have been investigated for these injuries to guide axonal regeneration and lead to functional recovery. We have designed a biologics-free hydrogel-based multi-channel conduit with defined microscale features to guide axonal outgrowth. To investigate extraneural vascular infiltration and its effects on functional recovery, we also designed a multi-microchannel conduit with defined regularly spaced micropores, orthogonal to the axon guidance channels. Using our custom-built Rapid Projection, Image-guided, Dynamic (RaPID) bioprinting system, we were able to fabricate each hydrogel conduit within minutes from a milliliter-volume prepolymer vat. With our state-of-the-art printing platform, we have achieved NGCs with a consistent channel wall width of 10 μm. We implanted the NGCs for 17 weeks in a murine sciatic nerve transection injury model. We assessed the functional recovery by dynamic gait analysis throughout the recovery period and by compound muscle action potential (CMAP) electrophysiology before NGC harvesting. Both the non-porous and micro-porous conduit groups led to functional nerve regeneration on par with the autograft group. Further, both conduit groups resulted in restoration of bulk motor function to pre-injury performance.

Authors

Institutions

Publication Details

Journal
Bioengineering & Translational Medicine
Published
2025-08-04
DOI
https://doi.org/10.1002/btm2.70057
Citations
1
Primary Topic
Nerve injury and regeneration
Type
article
Field-Weighted Citation Impact
0.91

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D printed nerve guidance conduit for biologics‐free nerve regeneration and vascular integration

Shaochen Chen, Susie Johnson, Jacob Schimelman, Zhenrui Shi et al.
1 citations
Bioengineering & Translational Medicine
Nerve injury and regeneration
0.91
article

3D printed nerve guidance conduit for biologics‐free nerve regeneration and vascular integration

Shaochen Chen, Susie Johnson, Jacob Schimelman, Zhenrui Shi, David B. Berry, Sophie Brown, Quyen T. Nguyen
article en
1 citations

Abstract

There is a clinical need for an effective nerve guidance conduit to treat peripheral nerve injuries. Many studies have explored different materials and active cues to guide neural regeneration, with some success. However, none have demonstrated a comparable or better functional recovery than the clinical standard autograft. Autografts are often insufficient for reconstruction of an injury to long nerves such as the sciatic or brachial plexus. Synthetic nerve guidance conduits (NGCs) have been investigated for these injuries to guide axonal regeneration and lead to functional recovery. We have designed a biologics-free hydrogel-based multi-channel conduit with defined microscale features to guide axonal outgrowth. To investigate extraneural vascular infiltration and its effects on functional recovery, we also designed a multi-microchannel conduit with defined regularly spaced micropores, orthogonal to the axon guidance channels. Using our custom-built Rapid Projection, Image-guided, Dynamic (RaPID) bioprinting system, we were able to fabricate each hydrogel conduit within minutes from a milliliter-volume prepolymer vat. With our state-of-the-art printing platform, we have achieved NGCs with a consistent channel wall width of 10 μm. We implanted the NGCs for 17 weeks in a murine sciatic nerve transection injury model. We assessed the functional recovery by dynamic gait analysis throughout the recovery period and by compound muscle action potential (CMAP) electrophysiology before NGC harvesting. Both the non-porous and micro-porous conduit groups led to functional nerve regeneration on par with the autograft group. Further, both conduit groups resulted in restoration of bulk motor function to pre-injury performance.

Bioengineering & Translational MedicineVol. 10(6)
University of California System (US), University of California San Diego (US), La Jolla Bioengineering Institute (US)
National Science Foundation, National Institutes of Health, National Institute of Child Health and Human Development, Eunice Kennedy Shriver National Institute of Child Health and Human Development
Openalex Percentile: Top 24%
Nerve injury and regeneration
0.91
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.