EEG channels selection for stroke patients rehabilitation using equilibrium optimizer

Abstract Stroke ranks as the second leading cause of death worldwide and is a major contributor to disability. Researchers have proposed various applications to assist in the rehabilitation of stroke patients, with brain-computer interfaces (BCIs) utilizing electroencephalograms (EEGs) showing particularly promising outcomes. However, the most challenging aspect of using BCI methods is effectively extracting and selecting the most significant features from the vast amount of EEG data available. This article addresses this problem by presenting an innovative optimization-based approach to the channel selection problem, employing a novel binary equilibrium optimizer (EO) as an optimization technique to identify the most relevant EEG channels. This method significantly enhances the accuracy of stroke patient rehabilitation outcomes while reducing computational complexity, avoiding overfitting, and minimizing user discomfort during clinical use. During the preprocessing step, conventional filters and the AICA-WT (automatic independent component analysis with wavelet transform) denoising technique are employed. Attributes are then computed for the time, entropy, and frequency domains. The EO algorithm is utilized to represent the EEG channel selection problem, transforming the features of each individual EEG into binary values and subsequently applying a k-nearest neighbor classifier technique to determine the accuracy rate. The proposed method demonstrates superior performance, achieving the highest accuracy rate of 99% with the HFD features, compared to the existing methods. In general, the proposed study provides a more reliable strategy by identifying a subject-specific reduced set of relevant electrodes and establishes a new benchmark in the field of stroke rehabilitation, highlighting the quality and potential impact of this work.

Authors

Institutions

Publication Details

Journal
Journal of Intelligent Systems
Published
2025-01-01
DOI
https://doi.org/10.1515/jisys-2024-0252
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EEG channels selection for stroke patients rehabilitation using equilibrium optimizer

Sharif Naser Makhadmeh, Zaid Abdi Alkareem Alyasseri, Mohammed Azmi Al-Betar
Journal of Intelligent Systems
EEG and Brain-Computer Interfaces
article

EEG channels selection for stroke patients rehabilitation using equilibrium optimizer

Sharif Naser Makhadmeh, Zaid Abdi Alkareem Alyasseri, Mohammed Azmi Al-Betar
article en

Abstract

Abstract Stroke ranks as the second leading cause of death worldwide and is a major contributor to disability. Researchers have proposed various applications to assist in the rehabilitation of stroke patients, with brain-computer interfaces (BCIs) utilizing electroencephalograms (EEGs) showing particularly promising outcomes. However, the most challenging aspect of using BCI methods is effectively extracting and selecting the most significant features from the vast amount of EEG data available. This article addresses this problem by presenting an innovative optimization-based approach to the channel selection problem, employing a novel binary equilibrium optimizer (EO) as an optimization technique to identify the most relevant EEG channels. This method significantly enhances the accuracy of stroke patient rehabilitation outcomes while reducing computational complexity, avoiding overfitting, and minimizing user discomfort during clinical use. During the preprocessing step, conventional filters and the AICA-WT (automatic independent component analysis with wavelet transform) denoising technique are employed. Attributes are then computed for the time, entropy, and frequency domains. The EO algorithm is utilized to represent the EEG channel selection problem, transforming the features of each individual EEG into binary values and subsequently applying a k-nearest neighbor classifier technique to determine the accuracy rate. The proposed method demonstrates superior performance, achieving the highest accuracy rate of 99% with the HFD features, compared to the existing methods. In general, the proposed study provides a more reliable strategy by identifying a subject-specific reduced set of relevant electrodes and establishes a new benchmark in the field of stroke rehabilitation, highlighting the quality and potential impact of this work.

Journal of Intelligent SystemsVol. 34(1)
Al-Ahliyya Amman University (JO), University of Jordan (JO), Ajman University (AE), City University Ajman (AE), King Abdullah University Hospital (JO), University of Kerbala (IQ), University of Kufa (IQ)
Ajman University
Openalex Percentile: Top 81%
EEG and Brain-Computer Interfaces
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.