Assessment and Comparison of 3D Conformal Radiotherapy With Volumetric Modulated Arc Therapy for Preserving Remaining Brain Volume in High-Grade Gliomas

Introduction Tri-modality therapy, consisting of maximal safe resection, concurrent chemo-radiation, and adjuvant chemotherapy, is the standard approach for the treatment of high-grade glioma (HGGs). Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) have excellent potential to reduce the doses to organs at risk (OARs) with optimal dose conformity. However, the literature on the dosimetric parameters for remaining brain volume (RBV) and its relative comparison is limited. Methods We conducted a retrospective study for which the inclusion criteria were being over the age of 18 years and having a histologically proven post-operative HGG with a Karnofsky performance score (KPS) >60. The prescription dose was similar in both techniques (60 Gray in 30 fractions at 2 Gray per fraction). The primary objective was to evaluate and compare the dosimetric profiles of V5, V10, V20, V30, V40, V50, and V60 of the RBV. The secondary objective was to document and compare the doses received by OARs in three-dimensional conformal radiotherapy (3D-CRT) and VMAT. Results The planning data of 24 patients were analyzed. The demographic profile was age (<40, 42%; > 40, 58%), male (58%) and female (42%), KPS (60, 12%; 70, 54%; 80, 33%), histopathological grade III (30%) and IV (70%), and tumor location (frontal 50%, parietal 21%, temporal 17%, and occipital 12%). In 79% of the patients, the tumor crossed midline. The VMAT plan showed superior dose conformity compared with the 3D-CRT plan (p-value 0.001). The low-to-medium dose volumes (V5, V10, V20, and V30) of the RBV were found to be statistically significant, thus favoring the 3D-CRT plan, but the medium-to-high dose volumes (V50 and V60), which were high in the 3D-CRT plan, favored the VMAT plan. However, the whole brain mean dose did not show any significant difference. Conclusion The VMAT plan showed superior dose conformity compared with the 3D-CRT plan. However, the RBV among the patients receiving the low doses was greater in the VMAT plan than in the 3D-CRT plan, while the RBV among those receiving high doses was significantly greater in the 3D-CRT plan.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-08-04
DOI
https://doi.org/10.7759/cureus.89335
Primary Topic
Glioma Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment and Comparison of 3D Conformal Radiotherapy With Volumetric Modulated Arc Therapy for Preserving Remaining Brain Volume in High-Grade Gliomas

Nilesh Mani, Anil K. Jaiswal, Harikesh Bahadur Singh, Samyak Chauhan et al.
1 links
Cureus
Glioma Diagnosis and Treatment
article

Assessment and Comparison of 3D Conformal Radiotherapy With Volumetric Modulated Arc Therapy for Preserving Remaining Brain Volume in High-Grade Gliomas

Nilesh Mani, Anil K. Jaiswal, Harikesh Bahadur Singh, Samyak Chauhan, Minakshi Mishra, Pritanjali Singh
article en

Abstract

Introduction Tri-modality therapy, consisting of maximal safe resection, concurrent chemo-radiation, and adjuvant chemotherapy, is the standard approach for the treatment of high-grade glioma (HGGs). Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) have excellent potential to reduce the doses to organs at risk (OARs) with optimal dose conformity. However, the literature on the dosimetric parameters for remaining brain volume (RBV) and its relative comparison is limited. Methods We conducted a retrospective study for which the inclusion criteria were being over the age of 18 years and having a histologically proven post-operative HGG with a Karnofsky performance score (KPS) >60. The prescription dose was similar in both techniques (60 Gray in 30 fractions at 2 Gray per fraction). The primary objective was to evaluate and compare the dosimetric profiles of V5, V10, V20, V30, V40, V50, and V60 of the RBV. The secondary objective was to document and compare the doses received by OARs in three-dimensional conformal radiotherapy (3D-CRT) and VMAT. Results The planning data of 24 patients were analyzed. The demographic profile was age (<40, 42%; > 40, 58%), male (58%) and female (42%), KPS (60, 12%; 70, 54%; 80, 33%), histopathological grade III (30%) and IV (70%), and tumor location (frontal 50%, parietal 21%, temporal 17%, and occipital 12%). In 79% of the patients, the tumor crossed midline. The VMAT plan showed superior dose conformity compared with the 3D-CRT plan (p-value 0.001). The low-to-medium dose volumes (V5, V10, V20, and V30) of the RBV were found to be statistically significant, thus favoring the 3D-CRT plan, but the medium-to-high dose volumes (V50 and V60), which were high in the 3D-CRT plan, favored the VMAT plan. However, the whole brain mean dose did not show any significant difference. Conclusion The VMAT plan showed superior dose conformity compared with the 3D-CRT plan. However, the RBV among the patients receiving the low doses was greater in the VMAT plan than in the 3D-CRT plan, while the RBV among those receiving high doses was significantly greater in the 3D-CRT plan.

CureusVol. 17(8)
Indira Gandhi Institute of Medical Sciences (IN), All India Institute of Medical Sciences (IN)
Zero hunger
Openalex Percentile: Top 73%
Glioma Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.