ECT Sensor for Symmetrical Robot Gripper Application

Electrical capacitance tomography (ECT) is an imaging technique for visualizing permittivity distributions in industrial processes. This paper first time explores application of ECT in robotic grippers. In this case, the electrode configuration significantly affects imaging quality. If a group of 4 electrodes is mounted on each finger of a three-finger symmetrical gripper, the gap between groups of electrodes will affect image reconstruction, and the sensitivity matrix should change accordingly. This study investigates the inter-group electrode gap to intra-group electrode gap ratio (GGR) from 1:1 to 25:1 by software through simulation and experiment. Image reconstruction was conducted using linear back projection (LBP) and Landweber iterations, incorporating weighted electrode pairs, multi-angle fusion and subsequent optimization. Both simulation and experiment confirm the effectiveness of optimized imaging strategies. For stratified and annular distributions, multi-angle and optimized fusion consistently achieved high correlation coefficients for all GGRs, exceeding 0.90/0.77 and 0.85/0.91, respectively. For two-object distributions, optimized fusion maintained a correlation coefficient above 0.80 within the GGR range of 2:1 to 14:1. Experimental results at GGR = 5 demonstrated the effectiveness of the proposed methods, achieving high correlation coefficients of 0.91/0.96 for stratified targets, 0.94/0.87 for annular targets, and 0.86/0.82 for two-object targets, which closely aligns with simulation results. These results demonstrate that optimizing GGR and incorporating weighted electrode pairs can significantly enhance ECT image quality. The proposed methodology establishes a foundation for integrating ECT into robotic grippers, enabling reliable internal structural characterization and analysis.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3595247
Citations
2
Primary Topic
Mechatronics Education and Applications
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ECT Sensor for Symmetrical Robot Gripper Application

Ruixiang Deng, Wuqiang Yang, Yang Hu, Hao Bai
2 citations
IEEE Transactions on Instrumentation and Measurement
Mechatronics Education and Applications
1.43
article

ECT Sensor for Symmetrical Robot Gripper Application

Ruixiang Deng, Wuqiang Yang, Yang Hu, Hao Bai
article en
2 citations

Abstract

Electrical capacitance tomography (ECT) is an imaging technique for visualizing permittivity distributions in industrial processes. This paper first time explores application of ECT in robotic grippers. In this case, the electrode configuration significantly affects imaging quality. If a group of 4 electrodes is mounted on each finger of a three-finger symmetrical gripper, the gap between groups of electrodes will affect image reconstruction, and the sensitivity matrix should change accordingly. This study investigates the inter-group electrode gap to intra-group electrode gap ratio (GGR) from 1:1 to 25:1 by software through simulation and experiment. Image reconstruction was conducted using linear back projection (LBP) and Landweber iterations, incorporating weighted electrode pairs, multi-angle fusion and subsequent optimization. Both simulation and experiment confirm the effectiveness of optimized imaging strategies. For stratified and annular distributions, multi-angle and optimized fusion consistently achieved high correlation coefficients for all GGRs, exceeding 0.90/0.77 and 0.85/0.91, respectively. For two-object distributions, optimized fusion maintained a correlation coefficient above 0.80 within the GGR range of 2:1 to 14:1. Experimental results at GGR = 5 demonstrated the effectiveness of the proposed methods, achieving high correlation coefficients of 0.91/0.96 for stratified targets, 0.94/0.87 for annular targets, and 0.86/0.82 for two-object targets, which closely aligns with simulation results. These results demonstrate that optimizing GGR and incorporating weighted electrode pairs can significantly enhance ECT image quality. The proposed methodology establishes a foundation for integrating ECT into robotic grippers, enabling reliable internal structural characterization and analysis.

IEEE Transactions on Instrumentation and MeasurementVol. 74
University of Manchester (GB)
University of Manchester
Affordable and clean energy
Openalex Percentile: Top 18%
Mechatronics Education and Applications
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.