Measurement Device for Corneal Static Biomechanical Properties Based on Negative Pressure Adhesion

Accurate measurement of corneal biomechanics plays a critical role in ophthalmic activities such as refractive surgery planning, keratoconus detection and glaucoma diagnosis. The current invasive measurement techniques and dynamic elastography methods are inherently limited by their inability to assess corneal static biomechanical properties in vivo. In this article, we describe a non-invasive corneal static biomechanical measurement system integrating negative pressure expansion measurement and control with spectral domain optical coherence tomography (SD-OCT) imaging. This system enables precise steady-state negative pressure regulation from 0 to 60 kPa, inducing controllable corneal deformation ranging from 0 to 600 μm. The system provides 0-60 kPa precision steady-state negative pressure regulation to induce 0-600 μm controlled corneal deformation, while synchronizing with SD-OCT for real-time deformation monitoring. The system acquires the static stress-strain relationship of the cornea through its steady-state inflation response and corresponding biomechanical analysis model, enabling non-invasive measurement of corneal static Young’s modulus. Our system measured the Young’s modulus of the artificial cornea as 2.33 ± 0.02 MPa, which is highly consistent with the value obtained from uniaxial compression testing (2.33 ± 0.02 MPa). This non-invasive measurement system overcomes the invasive limitations of traditional inflation tests and provides a novel clinical tool for corneal biomechanical assessment.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3595256
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement Device for Corneal Static Biomechanical Properties Based on Negative Pressure Adhesion

Tingwei Quan, Honghao Wang, D Zhao, Zhuoyu Zhang et al.
4 links
IEEE Transactions on Instrumentation and Measurement
Corneal surgery and disorders
article

Measurement Device for Corneal Static Biomechanical Properties Based on Negative Pressure Adhesion

Tingwei Quan, Honghao Wang, D Zhao, Zhuoyu Zhang, Zuwang Zhou, Shaoqun Zeng, Jia Lu, Zhongrui Wang, Hao Zhang, Xiaohua Lv, Xiuli Liu, Haijun Lv, Wu He, Ying Zhang, Y. Z. Qu
article en

Abstract

Accurate measurement of corneal biomechanics plays a critical role in ophthalmic activities such as refractive surgery planning, keratoconus detection and glaucoma diagnosis. The current invasive measurement techniques and dynamic elastography methods are inherently limited by their inability to assess corneal static biomechanical properties in vivo. In this article, we describe a non-invasive corneal static biomechanical measurement system integrating negative pressure expansion measurement and control with spectral domain optical coherence tomography (SD-OCT) imaging. This system enables precise steady-state negative pressure regulation from 0 to 60 kPa, inducing controllable corneal deformation ranging from 0 to 600 μm. The system provides 0-60 kPa precision steady-state negative pressure regulation to induce 0-600 μm controlled corneal deformation, while synchronizing with SD-OCT for real-time deformation monitoring. The system acquires the static stress-strain relationship of the cornea through its steady-state inflation response and corresponding biomechanical analysis model, enabling non-invasive measurement of corneal static Young’s modulus. Our system measured the Young’s modulus of the artificial cornea as 2.33 ± 0.02 MPa, which is highly consistent with the value obtained from uniaxial compression testing (2.33 ± 0.02 MPa). This non-invasive measurement system overcomes the invasive limitations of traditional inflation tests and provides a novel clinical tool for corneal biomechanical assessment.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Wuhan National Laboratory for Optoelectronics (CN)
National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities
Affordable and clean energy
Openalex Percentile: Top 72%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.