Advanced Signal Processing Algorithm-Based State Estimation and Denoising of ECG Signals for Biomedical Applications

State estimation of electrocardiography (ECG) signals plays a crucial role in effective cardiac monitoring systems and assists in the early detection of abnormalities. However, ECG signals are often contaminated by interfering noise such as baseline wander, power-line interference, and motion artifacts, which significantly hinder precise state estimation. To address these challenges, this paper proposes a particle filter (PF)-based method for ECG signal estimation, which effectively preserves clinically relevant waveform characteristics under nonlinear and non-stationary noise conditions. The technique is implemented in MATLAB using a synthetic ECG signal and is evaluated using fast Fourier transform, spectrogram analysis, power spectral density, autocorrelation, and wavelet transform. A comparative analysis reveals that the proposed PF-based method significantly outperforms baseline denoising techniques. Quantitatively, the process achieves a mean square error (MSE) of 0.001382, representing a 48.5% improvement over the variant without the attention mechanism (MSE = 0.002682). Additionally, the signal-to-noise ratio is enhanced by 6.3 dB, reaching 15.87 dB, the highest among all tested methods. The percentage root mean square difference is also reduced to 4.62%, indicating low signal distortion. Furthermore, the accuracy of R-peak identification reaches 98.5%, ensuring a better extraction of cardiac features. The proposed method demonstrates a runtime of 0.75 seconds for a 10-second ECG segment, confirming its suitability for real-time biomedical applications. The simulation results validate that the PF-based state estimation framework is not only more precise and robust to noise but also computationally efficient, making it ideal for ECG signal processing in wearable health monitoring and real-time cardiac diagnostics.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3595453
Citations
1
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.39

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Signal Processing Algorithm-Based State Estimation and Denoising of ECG Signals for Biomedical Applications

Nayef Alqahtani, Mohd. Maroof Siddiqui, Saad Arif, Naoufel Kraïem et al.
1 citations
IEEE Access
ECG Monitoring and Analysis
1.39
article

Advanced Signal Processing Algorithm-Based State Estimation and Denoising of ECG Signals for Biomedical Applications

Nayef Alqahtani, Mohd. Maroof Siddiqui, Saad Arif, Naoufel Kraïem, Kamran Shah, Muhammad Attique Khan
article en
1 citations

Abstract

State estimation of electrocardiography (ECG) signals plays a crucial role in effective cardiac monitoring systems and assists in the early detection of abnormalities. However, ECG signals are often contaminated by interfering noise such as baseline wander, power-line interference, and motion artifacts, which significantly hinder precise state estimation. To address these challenges, this paper proposes a particle filter (PF)-based method for ECG signal estimation, which effectively preserves clinically relevant waveform characteristics under nonlinear and non-stationary noise conditions. The technique is implemented in MATLAB using a synthetic ECG signal and is evaluated using fast Fourier transform, spectrogram analysis, power spectral density, autocorrelation, and wavelet transform. A comparative analysis reveals that the proposed PF-based method significantly outperforms baseline denoising techniques. Quantitatively, the process achieves a mean square error (MSE) of 0.001382, representing a 48.5% improvement over the variant without the attention mechanism (MSE = 0.002682). Additionally, the signal-to-noise ratio is enhanced by 6.3 dB, reaching 15.87 dB, the highest among all tested methods. The percentage root mean square difference is also reduced to 4.62%, indicating low signal distortion. Furthermore, the accuracy of R-peak identification reaches 98.5%, ensuring a better extraction of cardiac features. The proposed method demonstrates a runtime of 0.75 seconds for a 10-second ECG segment, confirming its suitability for real-time biomedical applications. The simulation results validate that the PF-based state estimation framework is not only more precise and robust to noise but also computationally efficient, making it ideal for ECG signal processing in wearable health monitoring and real-time cardiac diagnostics.

IEEE AccessVol. 13
Prince Mohammad bin Fahd University (SA), Korea University (KR), Dhofar University (OM), King Faisal University (SA), King Khalid University (SA)
King Faisal University
Openalex Percentile: Top 16%
ECG Monitoring and Analysis
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.