Calibration of Electron Microscopes Through Deep Learning and Bayesian Optimization

Electron microscopes can create images at atomic resolution, enabling key developments across many scientific fields. To obtain high-resolution images, the inherent imperfections in the electromagnetic lenses have to be overcome by frequent and extensive calibration. Currently, this calibration is typically performed or monitored by experts, making it expensive and time-consuming. To resolve this, this paper proposes a data-driven solution for automated, image-based calibration of a Scanning Transmission Electron Microscope (STEM). The method uses deep learning to interpret the high-dimensional image, also called the Ronchigram, produced by the STEM, providing a quality index that quantifies the distance of the current image from its calibrated state. Specifically, we perform transfer learning on an adapted ResNet18 architecture using a large data set of simulated Ronchigrams. Afterward, Gaussian process regression models how calibration settings affect this quality index from limited samples. Subsequently, candidate calibration settings are selected online using Bayesian optimization with a novel acquisition function tailored to this problem. When applied to the STEM, the proposed method consistently calibrates defocus and two-fold astigmatism in just a few steps. Compared to existing automated calibration methods, the proposed method can consistently achieve similar performance in less time. For this reason, our approach potentially reduces expert involvement and improves the overall throughput of the STEM. Moreover, the data-driven nature of the proposed method suggests it could be adapted to calibrate additional types of imperfections, positioning it as a flexible tool for enhancing STEM performance, provided that representative data can be generated from the simulator.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3595430
Citations
1
Primary Topic
Electron and X-Ray Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.66

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Calibration of Electron Microscopes Through Deep Learning and Bayesian Optimization

Maurits Diephuis, Duarte Antunes, W.P.M.H. Heemels, R.A.C. van Zuijlen et al.
1 citations
IEEE Access
Electron and X-Ray Spectroscopy Techniques
0.66
article

Calibration of Electron Microscopes Through Deep Learning and Bayesian Optimization

Maurits Diephuis, Duarte Antunes, W.P.M.H. Heemels, R.A.C. van Zuijlen, J. S. van Hulst, Narges Javaheri
article en
1 citations

Abstract

Electron microscopes can create images at atomic resolution, enabling key developments across many scientific fields. To obtain high-resolution images, the inherent imperfections in the electromagnetic lenses have to be overcome by frequent and extensive calibration. Currently, this calibration is typically performed or monitored by experts, making it expensive and time-consuming. To resolve this, this paper proposes a data-driven solution for automated, image-based calibration of a Scanning Transmission Electron Microscope (STEM). The method uses deep learning to interpret the high-dimensional image, also called the Ronchigram, produced by the STEM, providing a quality index that quantifies the distance of the current image from its calibrated state. Specifically, we perform transfer learning on an adapted ResNet18 architecture using a large data set of simulated Ronchigrams. Afterward, Gaussian process regression models how calibration settings affect this quality index from limited samples. Subsequently, candidate calibration settings are selected online using Bayesian optimization with a novel acquisition function tailored to this problem. When applied to the STEM, the proposed method consistently calibrates defocus and two-fold astigmatism in just a few steps. Compared to existing automated calibration methods, the proposed method can consistently achieve similar performance in less time. For this reason, our approach potentially reduces expert involvement and improves the overall throughput of the STEM. Moreover, the data-driven nature of the proposed method suggests it could be adapted to calibrate additional types of imperfections, positioning it as a flexible tool for enhancing STEM performance, provided that representative data can be generated from the simulator.

IEEE AccessVol. 13
Thermo Fisher Scientific (Netherlands) (NL), Eindhoven University of Technology (NL)
ITEA, Bundesministerium für Bildung und Forschung, Ministerie van Economische Zaken en Klimaat
Openalex Percentile: Top 29%
Electron and X-Ray Spectroscopy Techniques
0.66
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.