Structural Design and Analysis of 14 T Animal MRI Superconducting Magnet

High field magnetic resonance imaging (HF-MRI) systems can achieve higher image resolution and sensitivity, resulting in better image quality and more biological information, which has significant value in life science and clinical medicine applications. The development of high field magnetic resonance imaging system depends on the development of high field superconducting magnet. High field MRI superconducting magnet need to solve problems such as high magnetic field uniformity requirements, large stray field range, high coil electromagnetic stress, and shrinkage stress in low-temperature systems. This article introduces the design and optimization process of 14 T@ 175 warm bore size animal MRI superconducting magnet. We used a nonlinear multi-objective programming algorithm to simultaneously optimize warm bore space (diameter 175mm), magnetic field homogeneity and the stray magnetic field (5 Gauss line) for a 14 T MRI magnet. The spatial position, electromagnetic density, and electromagnetic stress of different coils are obtained, and the design stability of magnet coil is evaluated using coil loading ratio and current safety margin. In addition, the magnet coil former is designed, and the finite element method is used to perform mechanical simulation analysis on the coil former. The optimization results show that the warm bore of the magnet is 175 mm, and the homogeneity of the magnet design is 1.1 ppm@ 60 mm DSV, magnet stray field (5 Gauss line) is 2.9 m in the axial direction and 2.4 m in the radial direction from the center of the magnetic field. The minimum safety margin of the magnet coil is 10.6%, and the maximum hoop stress of the magnet coil is 225Mpa. The magnet meets the design requirements and provides necessary reference for the engineering prototype of the 14 T animal MRI superconducting magnet.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Applied Superconductivity
Published
2025-08-04
DOI
https://doi.org/10.1109/tasc.2025.3595642
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Structural Design and Analysis of 14 T Animal MRI Superconducting Magnet

Peng Gao, Lei Wu, Chao Zhou, Zhan Zhang
IEEE Transactions on Applied Superconductivity
Superconducting Materials and Applications
article

Structural Design and Analysis of 14 T Animal MRI Superconducting Magnet

Peng Gao, Lei Wu, Chao Zhou, Zhan Zhang
article en

Abstract

High field magnetic resonance imaging (HF-MRI) systems can achieve higher image resolution and sensitivity, resulting in better image quality and more biological information, which has significant value in life science and clinical medicine applications. The development of high field magnetic resonance imaging system depends on the development of high field superconducting magnet. High field MRI superconducting magnet need to solve problems such as high magnetic field uniformity requirements, large stray field range, high coil electromagnetic stress, and shrinkage stress in low-temperature systems. This article introduces the design and optimization process of 14 T@ 175 warm bore size animal MRI superconducting magnet. We used a nonlinear multi-objective programming algorithm to simultaneously optimize warm bore space (diameter 175mm), magnetic field homogeneity and the stray magnetic field (5 Gauss line) for a 14 T MRI magnet. The spatial position, electromagnetic density, and electromagnetic stress of different coils are obtained, and the design stability of magnet coil is evaluated using coil loading ratio and current safety margin. In addition, the magnet coil former is designed, and the finite element method is used to perform mechanical simulation analysis on the coil former. The optimization results show that the warm bore of the magnet is 175 mm, and the homogeneity of the magnet design is 1.1 ppm@ 60 mm DSV, magnet stray field (5 Gauss line) is 2.9 m in the axial direction and 2.4 m in the radial direction from the center of the magnetic field. The minimum safety margin of the magnet coil is 10.6%, and the maximum hoop stress of the magnet coil is 225Mpa. The magnet meets the design requirements and provides necessary reference for the engineering prototype of the 14 T animal MRI superconducting magnet.

IEEE Transactions on Applied SuperconductivityVol. 35(7)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Institute of Plasma Physics (CN)
Openalex Percentile: Top 82%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.