Comparison Study of a-Se/CMOS Detector and Commercial Alternatives for High-Resolution X-Ray Imaging of Soil Structure

Computed tomography (CT) serves as a noninvasive technique for pinpointing specific areas within objects, facilitating the examination of soil distributions and localized flow processes within soil pore networks. CT scanning yields cross-sectional sequences that unveil insights into the internal structure of pore networks, which is crucial for understanding root–soil interactions. In this investigation, we explore the potential of employing a high-resolution amorphous selenium (a-Se) direct conversion detector coupled with complementary metal–oxide–semiconductor (CMOS) readouts for micro-CT scanning of soil matrices. This approach aims to visualize the aggregation status and pore network connectivity within intact soil. In addition, we compare the capabilities of the a-Se/CMOS detector with other commercially available detectors evaluating performance in terms of spatial resolution, noise levels, and overall imaging quality. The integration of a-Se’s intrinsic high spatial resolution with small-pixel CMOS readouts enables detailed visualization of soil aggregates in plant samples. By varying X-ray energy and soil thickness, we achieved a spatial resolution of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\leq$</tex-math></inline-formula> 25 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula>m and a noise-limited performance of eight photons/pixel at 20 keV. Although thick soil presents challenges due to high X-ray attenuation, finer details are discernible in thinner samples, underscoring the importance of careful selection of soil thickness and container material.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on AgriFood Electronics
Published
2025-08-04
DOI
https://doi.org/10.1109/tafe.2025.3590771
Primary Topic
X-ray Spectroscopy and Fluorescence Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison Study of a-Se/CMOS Detector and Commercial Alternatives for High-Resolution X-Ray Imaging of Soil Structure

N. Robert Bennett, W. Cheng, Adam Wang, Shiva Abbaszadeh et al.
IEEE Transactions on AgriFood Electronics
X-ray Spectroscopy and Fluorescence Analysis
article

Comparison Study of a-Se/CMOS Detector and Commercial Alternatives for High-Resolution X-Ray Imaging of Soil Structure

N. Robert Bennett, W. Cheng, Adam Wang, Shiva Abbaszadeh, Michael G. Farrier, Daniel Fiallo
article en

Abstract

Computed tomography (CT) serves as a noninvasive technique for pinpointing specific areas within objects, facilitating the examination of soil distributions and localized flow processes within soil pore networks. CT scanning yields cross-sectional sequences that unveil insights into the internal structure of pore networks, which is crucial for understanding root–soil interactions. In this investigation, we explore the potential of employing a high-resolution amorphous selenium (a-Se) direct conversion detector coupled with complementary metal–oxide–semiconductor (CMOS) readouts for micro-CT scanning of soil matrices. This approach aims to visualize the aggregation status and pore network connectivity within intact soil. In addition, we compare the capabilities of the a-Se/CMOS detector with other commercially available detectors evaluating performance in terms of spatial resolution, noise levels, and overall imaging quality. The integration of a-Se’s intrinsic high spatial resolution with small-pixel CMOS readouts enables detailed visualization of soil aggregates in plant samples. By varying X-ray energy and soil thickness, we achieved a spatial resolution of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\leq$</tex-math></inline-formula> 25 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\mu$</tex-math></inline-formula>m and a noise-limited performance of eight photons/pixel at 20 keV. Although thick soil presents challenges due to high X-ray attenuation, finer details are discernible in thinner samples, underscoring the importance of careful selection of soil thickness and container material.

IEEE Transactions on AgriFood ElectronicsVol. 3(2)
University of California, Santa Cruz (US), North Central Michigan College (US), Stanford University (US)
Zero hunger
Openalex Percentile: Top 74%
X-ray Spectroscopy and Fluorescence Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.