Scanning Electrochemical Impedance Microscopy-Based Assessment of Glucose Biosensors

Scanning electrochemical impedance microscopy (SEIM) was assessed as an electrochemical method for developing glucose biosensors based on glucose oxidase (GOx). To determine the lowest detectable GOx activity, scanning electrochemical microscopy (SECM) in the feedback mode (FB-SECM) was applied. During the measurement procedure, an ultramicroelectrode (UME) was moved vertically over the surface modified by immobilized GOx. A positive feedback response of the FB-SECM mode was determined during the assessment of surfaces modified by 5 fg/mm<sup>2</sup> to 20 μg/mm<sup>2</sup> surface concentration of GOx. The lowest surface concentration of GOx, which still provided reliable measurement results, was 50 fg/mm<sup>2</sup>. The approach curves registered using the FB-SECM mode were assessed using a mathematical model adapted for the calculation of reaction kinetics by SECM. According to this model, the reaction kinetics constant λ was calculated for differently modified surfaces in the presence of the same glucose concentration. For the surface not modified by GOx, the constant λ was determined to be 0.14, while for the GOx-modified surface λ gradually increased with increasing GOx surface concentrations, the λ value reached 0.34 when it was determined on the surfaces modified by 500 ng/mm<sup>2</sup> of GOx. Any statistically significant changes in FB-SECM were detected when the surface concentration of GOx exceeded 50 pg/mm<sup>2</sup>. Notably, localized electrochemical impedance measurements using the SEIM mode enabled one to detect GOx activity even when GOx was immobilized on a nonconductive substrate surface. The results show that redox competition-based SEIM can be used to determine glucose concentrations in the range of 2-20 mM, while using 10 Hz AC perturbation. An FB-SECM configuration allows the reuse of the ultramicroelectrode while providing the localized impedance-based glucose concentration and enzyme activity measurements.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-08-04
DOI
https://doi.org/10.1021/acs.langmuir.5c02292
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Scanning Electrochemical Impedance Microscopy-Based Assessment of Glucose Biosensors

Sheng‐Tung Huang, Antanas Zinovičius, Timas Merkelis, Arūnas Ramanavičius et al.
Langmuir
Electrochemical sensors and biosensors
article

Scanning Electrochemical Impedance Microscopy-Based Assessment of Glucose Biosensors

Sheng‐Tung Huang, Antanas Zinovičius, Timas Merkelis, Arūnas Ramanavičius, Justė Rožėnė, Sigita Bendinskaite, Inga Morkvėnaitė
article en

Abstract

Scanning electrochemical impedance microscopy (SEIM) was assessed as an electrochemical method for developing glucose biosensors based on glucose oxidase (GOx). To determine the lowest detectable GOx activity, scanning electrochemical microscopy (SECM) in the feedback mode (FB-SECM) was applied. During the measurement procedure, an ultramicroelectrode (UME) was moved vertically over the surface modified by immobilized GOx. A positive feedback response of the FB-SECM mode was determined during the assessment of surfaces modified by 5 fg/mm<sup>2</sup> to 20 μg/mm<sup>2</sup> surface concentration of GOx. The lowest surface concentration of GOx, which still provided reliable measurement results, was 50 fg/mm<sup>2</sup>. The approach curves registered using the FB-SECM mode were assessed using a mathematical model adapted for the calculation of reaction kinetics by SECM. According to this model, the reaction kinetics constant λ was calculated for differently modified surfaces in the presence of the same glucose concentration. For the surface not modified by GOx, the constant λ was determined to be 0.14, while for the GOx-modified surface λ gradually increased with increasing GOx surface concentrations, the λ value reached 0.34 when it was determined on the surfaces modified by 500 ng/mm<sup>2</sup> of GOx. Any statistically significant changes in FB-SECM were detected when the surface concentration of GOx exceeded 50 pg/mm<sup>2</sup>. Notably, localized electrochemical impedance measurements using the SEIM mode enabled one to detect GOx activity even when GOx was immobilized on a nonconductive substrate surface. The results show that redox competition-based SEIM can be used to determine glucose concentrations in the range of 2-20 mM, while using 10 Hz AC perturbation. An FB-SECM configuration allows the reuse of the ultramicroelectrode while providing the localized impedance-based glucose concentration and enzyme activity measurements.

LangmuirVol. 41(45)
National Taipei University of Technology (TW), Vilnius Gediminas Technical University (LT), Vilnius University (LT), Biochemical Society (GB), Center for Physical Sciences and Technology (LT), Vilnius University of Applied Sciences (LT), UPMC Center for High Value Health Care (US)
Lietuvos Mokslo Taryba, National Taipei University of Technology
Affordable and clean energy
Openalex Percentile: Top 82%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.