Behaviour of a novel functionally graded 3D re-entrant lattice reinforced high-performance concrete under static and dynamic compression

This paper presents a systematic experimental study on the static and dynamic mechanical behaviour of high-performance concrete (HPC) reinforced with 3D re-entrant lattice, accounting for the effect of functionally gradient design. The uniform 3D re-entrant lattice (U) and the corresponding vertically positively and negatively graded lattices (FG1 and FG2) were designed and manufactured with 3D printing. The plain HPC (P-HPC) and HPC reinforced with U (U-HPC), FG1 (G1-HPC) and FG2 (G2-HPC) were fabricated accordingly. Static compressive and split Hopkinson pressure bar tests were then conducted to investigate the static and dynamic compressive behaviour of 3D re-entrant lattice reinforced HPC under various strain rates (i.e., 0, 28.1, 50.6, 72.0 and 100.6 s −1 ). Results indicate that the static compressive strength of HPC specimens is slightly improved owing to re-entrant lattice reinforcement, while the static dissipated energy of P-HPC is 55.7 %, 53.2 % and 57.5 % lower than that of U-HPC, G1-HPC and G2-HPC, respectively. Regarding dynamic compressive behaviour, although the dynamic strength of P-HPC is 11.3–24.6 % higher than that of lattice reinforced HPC at a strain rate of around 30 s −1 , with the further increase of strain rates, the re-entrant lattice reinforced HPC presents higher strength improvement. G2-HPC has the highest dynamic compressive strength of 198.3 MPa at a strain rate of approximately 100.6 s −1 , followed by G1-HPC, P-HPC and U-HPC. At low strain rates, the plain and lattice reinforced HPC exhibit the similar energy absorption. When the strain rate reaches around 100.6 s −1 , U-HPC, G1-HPC and G2-HPC exhibit a 29.8 %, 36.8 % and 54.3 %, respectively higher dissipated energy than P-HPC. The gradient design of lattice reinforcement brings a more gradual and smooth dissipation of energy, thereby improving the overall energy absorption capacity. The excellent dynamic compressive behaviour of functionally graded 3D re-entrant lattice reinforced HPC offers a promising solution for protective structures subjected to high strain rates, including impact, blast, and seismic loadings.

Authors

Institutions

Publication Details

Journal
Cement and Concrete Composites
Published
2025-08-04
DOI
https://doi.org/10.1016/j.cemconcomp.2025.106261
Citations
1
Primary Topic
Innovative concrete reinforcement materials
Type
article
Field-Weighted Citation Impact
0.95

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behaviour of a novel functionally graded 3D re-entrant lattice reinforced high-performance concrete under static and dynamic compression

Dianwei Gao, Yiwei Xuan, Mingzhong Zhang
1 citations
Cement and Concrete Composites
Innovative concrete reinforcement materials
0.95
article

Behaviour of a novel functionally graded 3D re-entrant lattice reinforced high-performance concrete under static and dynamic compression

Dianwei Gao, Yiwei Xuan, Mingzhong Zhang
article en
1 citations

Abstract

This paper presents a systematic experimental study on the static and dynamic mechanical behaviour of high-performance concrete (HPC) reinforced with 3D re-entrant lattice, accounting for the effect of functionally gradient design. The uniform 3D re-entrant lattice (U) and the corresponding vertically positively and negatively graded lattices (FG1 and FG2) were designed and manufactured with 3D printing. The plain HPC (P-HPC) and HPC reinforced with U (U-HPC), FG1 (G1-HPC) and FG2 (G2-HPC) were fabricated accordingly. Static compressive and split Hopkinson pressure bar tests were then conducted to investigate the static and dynamic compressive behaviour of 3D re-entrant lattice reinforced HPC under various strain rates (i.e., 0, 28.1, 50.6, 72.0 and 100.6 s −1 ). Results indicate that the static compressive strength of HPC specimens is slightly improved owing to re-entrant lattice reinforcement, while the static dissipated energy of P-HPC is 55.7 %, 53.2 % and 57.5 % lower than that of U-HPC, G1-HPC and G2-HPC, respectively. Regarding dynamic compressive behaviour, although the dynamic strength of P-HPC is 11.3–24.6 % higher than that of lattice reinforced HPC at a strain rate of around 30 s −1 , with the further increase of strain rates, the re-entrant lattice reinforced HPC presents higher strength improvement. G2-HPC has the highest dynamic compressive strength of 198.3 MPa at a strain rate of approximately 100.6 s −1 , followed by G1-HPC, P-HPC and U-HPC. At low strain rates, the plain and lattice reinforced HPC exhibit the similar energy absorption. When the strain rate reaches around 100.6 s −1 , U-HPC, G1-HPC and G2-HPC exhibit a 29.8 %, 36.8 % and 54.3 %, respectively higher dissipated energy than P-HPC. The gradient design of lattice reinforcement brings a more gradual and smooth dissipation of energy, thereby improving the overall energy absorption capacity. The excellent dynamic compressive behaviour of functionally graded 3D re-entrant lattice reinforced HPC offers a promising solution for protective structures subjected to high strain rates, including impact, blast, and seismic loadings.

Cement and Concrete CompositesVol. 164
Shenyang University of Technology (CN), University College London (GB)
Royal Society, University College London, National Natural Science Foundation of China
Sustainable cities and communities
Openalex Percentile: Top 23%
Innovative concrete reinforcement materials
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.