A self-reference approach to synthetic aperture digital holographic microscopy

Synthetic aperture digital holographic microscopy (SA-DHM) enhances resolution and mitigates noise artifacts beyond the capabilities of conventional digital holographic microscopy. Traditional implementations rely on acquiring multiple holograms under different illumination angles, followed by a complex reconstruction process in the spatial frequency domain. In this work, we review a recently proposed single-exposure SA-DHM system capable of real-time numerical reconstruction. The design employs a modular framework comprising an illumination module and a self-referencing detection unit, both of which can be easily integrated into standard life-science microscopes with minimal cost and alignment effort. A theoretical image formation model allows real-time incorporation of non-blind deconvolution, enabling recovery of fine structural details. Experimental validation across diverse biological samples demonstrates the method’s practical effectiveness, offering substantial improvements in resolution and noise suppression over conventional coherent DHM.

Authors

Institutions

Publication Details

Published
2025-08-04
DOI
https://doi.org/10.1117/12.3066515
Primary Topic
Digital Holography and Microscopy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A self-reference approach to synthetic aperture digital holographic microscopy

Bryan M. Hennelly, Zhengyuan Tang
Digital Holography and Microscopy
article

A self-reference approach to synthetic aperture digital holographic microscopy

Bryan M. Hennelly, Zhengyuan Tang
article en

Abstract

Synthetic aperture digital holographic microscopy (SA-DHM) enhances resolution and mitigates noise artifacts beyond the capabilities of conventional digital holographic microscopy. Traditional implementations rely on acquiring multiple holograms under different illumination angles, followed by a complex reconstruction process in the spatial frequency domain. In this work, we review a recently proposed single-exposure SA-DHM system capable of real-time numerical reconstruction. The design employs a modular framework comprising an illumination module and a self-referencing detection unit, both of which can be easily integrated into standard life-science microscopes with minimal cost and alignment effort. A theoretical image formation model allows real-time incorporation of non-blind deconvolution, enabling recovery of fine structural details. Experimental validation across diverse biological samples demonstrates the method’s practical effectiveness, offering substantial improvements in resolution and noise suppression over conventional coherent DHM.

National University of Ireland, Maynooth (IE)
Openalex Percentile: Top 86%
Digital Holography and Microscopy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A self-reference approach to synthetic aperture digital holographic microscopy — Bryan M. Hennelly, Zhengyuan Tang · (2025) | TGRS Research Map | TGRS