Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report

Significant cases of methemoglobinemia will cause a signal interference in traditional dual-wavelength pulse oximetry leading to the classic finding of “refractory hypoxemia”. As smartwatches begin to incorporate pulse oximetry capabilities, it is unclear whether these devices will demonstrate the same type of interference in the presence of methemoglobinemia. This article reports a case where a patient’s Apple Watch© reported a hypoxemia alert in the setting of phenazopyridine induce methemoglobinemia. This is a case report of a 71-year-old female whose Apple Watch© reported a hypoxemia alarm in the setting of methemoglobinemia caused by phenazopyridine use. The patient’s smartwatch began signaling hypoxemia alerts the day before she noticed clinical cyanosis. 24 hours after the hypoxemia alerts began, she presented to the Emergency Department (ED) with shortness of breath and blue discoloration of skin. The Apple Watch© recorded oxygen saturation readings between 73% and 86%. Upon arrival to the ED, the patient’s SpO2 was 84% on traditional hospital-grade dual-wavelength pulse oximetry and her methemoglobin level was 19.8%. Her symptoms and methemoglobinemia resolved after administration of 1 mg/kg of IV methylene blue. Pulse oximetry used in smartwatch technology can trigger a hypoxemia alarm in the presence of drug-induced methemoglobinemia. If demonstrated to be a reproducible finding, smartwatch technology has the potential to be used as part of an early detection system for clinically significant methemoglobinemia.

Authors

Institutions

Publication Details

Journal
Journal of Medical Toxicology
Published
2025-08-04
DOI
https://doi.org/10.1007/s13181-025-01090-9
Primary Topic
Methemoglobinemia and Tumor Lysis Syndrome
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report

Leann N Tulisiak, Mackenzie E Loesing, Alexander Ljungberg, Eric E Kaczor
Journal of Medical Toxicology
Methemoglobinemia and Tumor Lysis Syndrome
article

Smartwatch Detection of Refractory Hypoxemia in Phenazopyridine-Induced Methemoglobinemia: A Case Report

Leann N Tulisiak, Mackenzie E Loesing, Alexander Ljungberg, Eric E Kaczor
article en

Abstract

Significant cases of methemoglobinemia will cause a signal interference in traditional dual-wavelength pulse oximetry leading to the classic finding of “refractory hypoxemia”. As smartwatches begin to incorporate pulse oximetry capabilities, it is unclear whether these devices will demonstrate the same type of interference in the presence of methemoglobinemia. This article reports a case where a patient’s Apple Watch© reported a hypoxemia alert in the setting of phenazopyridine induce methemoglobinemia. This is a case report of a 71-year-old female whose Apple Watch© reported a hypoxemia alarm in the setting of methemoglobinemia caused by phenazopyridine use. The patient’s smartwatch began signaling hypoxemia alerts the day before she noticed clinical cyanosis. 24 hours after the hypoxemia alerts began, she presented to the Emergency Department (ED) with shortness of breath and blue discoloration of skin. The Apple Watch© recorded oxygen saturation readings between 73% and 86%. Upon arrival to the ED, the patient’s SpO2 was 84% on traditional hospital-grade dual-wavelength pulse oximetry and her methemoglobin level was 19.8%. Her symptoms and methemoglobinemia resolved after administration of 1 mg/kg of IV methylene blue. Pulse oximetry used in smartwatch technology can trigger a hypoxemia alarm in the presence of drug-induced methemoglobinemia. If demonstrated to be a reproducible finding, smartwatch technology has the potential to be used as part of an early detection system for clinically significant methemoglobinemia.

Journal of Medical ToxicologyVol. 21(4)
University at Buffalo, State University of New York (US)
Openalex Percentile: Top 70%
Methemoglobinemia and Tumor Lysis Syndrome
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.