Effect of rotation on forced turbulent flow and heat transfer in a ribbed U-duct

The paper presents a method and simulation results for turbulent airflow and heat transfer in a U-shaped square duct with straight sections and with two ribbed opposite sides. For a flow with Reynolds number of 6·104 and Prandtl number of 2.5, the numerical solution method was validated by comparing the simulated and experimental data on local heat and mass transfer in geometrically identical U-ducts; the ribs inclined to the duct axis by 45 and 60 deg. For one of these ducts with the rib inclination angle of 45 deg (at the same Reynolds number and Prandtl number of 0.71), the flow patterns and heat transfer were calculated for a stationary state and for a mode with rotation (with the rotation parameter values of 0.1 and 0.25). The rotation axis is perpendicular to the duct axis and parallel to the duct bending plane. The numerical data for the U-shaped duct are compared with the data for a fully developed (periodic) flow and heat transfer for a straight duct with ribbing. It is shown that for a U-duct, the effect of rotation has a positive influence on heat transfer enhancement.

Authors

Institutions

Publication Details

Journal
Thermophysics and Aeromechanics
Published
2025-07-25
DOI
https://doi.org/10.1134/s0869864324060015
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of rotation on forced turbulent flow and heat transfer in a ribbed U-duct

В. В. Рис, A. M. Levchenya, С. А. Галаев, I. A. Ignatiev
Thermophysics and Aeromechanics
Cyclone Separators and Fluid Dynamics
article

Effect of rotation on forced turbulent flow and heat transfer in a ribbed U-duct

В. В. Рис, A. M. Levchenya, С. А. Галаев, I. A. Ignatiev
article en

Abstract

The paper presents a method and simulation results for turbulent airflow and heat transfer in a U-shaped square duct with straight sections and with two ribbed opposite sides. For a flow with Reynolds number of 6·104 and Prandtl number of 2.5, the numerical solution method was validated by comparing the simulated and experimental data on local heat and mass transfer in geometrically identical U-ducts; the ribs inclined to the duct axis by 45 and 60 deg. For one of these ducts with the rib inclination angle of 45 deg (at the same Reynolds number and Prandtl number of 0.71), the flow patterns and heat transfer were calculated for a stationary state and for a mode with rotation (with the rotation parameter values of 0.1 and 0.25). The rotation axis is perpendicular to the duct axis and parallel to the duct bending plane. The numerical data for the U-shaped duct are compared with the data for a fully developed (periodic) flow and heat transfer for a straight duct with ribbing. It is shown that for a U-duct, the effect of rotation has a positive influence on heat transfer enhancement.

Thermophysics and AeromechanicsVol. 31(6)
Peter the Great St. Petersburg Polytechnic University (RU)
Affordable and clean energy
Openalex Percentile: Top 80%
Cyclone Separators and Fluid Dynamics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.