Analysis of Borepile Foundation Bearing Capacity in Building Construction Projects with Pile Driving Analyzer Test

In the construction process, a building requires good planning, because structural elements must be able to receive loads in the form of axial directional loads such as gravitational loads as well as lateral directional loads such as wind loads and earthquake loads, all of which will later be passed on to the lower structure, namely the foundation. One of the things that is reviewed from the foundation is the value of the carrying capacity, to find out the value of the carrying capacity of a foundation can be calculated theoretically based on data from soil investigations in the field. Meanwhile, the Pile Driving Analyzer (PDA) is used to verify the results of the calculation. This study aims to calculate and analyze the bearing capacity of the foundation compared to the results of PDA. The method used is the Schmertmann & Nottingham method as well as the Mayerhoff method. The results of this study are carrying capacity using the Schmertmann & Nottingham method based on the results of the sondir test at the S1 point obtained a result of 804.15 tons, at the S2 sondir point the result was 761.99 tons, the S3 sondir point was 823.45 tons and at the S4 sondir point of 841.68 tons. The carrying capacity using the Meyerhoff method based on the results of the sondir test at the S1 point obtained a result of 572.39 tons, the S2 sondir point was 568.93 tons, the S3 sondir point was 568.84, and the S4 sondir point was 562.4 tons. The largest ultimate bearing capacity (Qu) value is obtained from the Schmertmann & Nottingham method at the sondir point S4, The smallest ultimate bearing capacity (Qu) value is obtained from the Meyerhoff method at the sondir point S4. The calculation results that show the least difference and are closest to the PDA are using the Meyerhoff method at the S4 sondir point and the BP-109 PDA with a difference of 115.5 tons. The Schmertmann & Nottingham method shows much greater results than PDA calculations

Authors

Institutions

Publication Details

Journal
Interdiciplinary Journal and Hummanity (INJURITY)
Published
2025-08-04
DOI
https://doi.org/10.58631/injurity.v4i8.1461
Primary Topic
Geotechnical and construction materials studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Borepile Foundation Bearing Capacity in Building Construction Projects with Pile Driving Analyzer Test

Flavia Aurelia Hidayat, Muhammad Hafizh Prasetyo, Hardian Tri Guntoro, Ingrid Multi Rezeki
1 links
Interdiciplinary Journal and Hummanity (INJURITY)
Geotechnical and construction materials studies
article

Analysis of Borepile Foundation Bearing Capacity in Building Construction Projects with Pile Driving Analyzer Test

Flavia Aurelia Hidayat, Muhammad Hafizh Prasetyo, Hardian Tri Guntoro, Ingrid Multi Rezeki
article en

Abstract

In the construction process, a building requires good planning, because structural elements must be able to receive loads in the form of axial directional loads such as gravitational loads as well as lateral directional loads such as wind loads and earthquake loads, all of which will later be passed on to the lower structure, namely the foundation. One of the things that is reviewed from the foundation is the value of the carrying capacity, to find out the value of the carrying capacity of a foundation can be calculated theoretically based on data from soil investigations in the field. Meanwhile, the Pile Driving Analyzer (PDA) is used to verify the results of the calculation. This study aims to calculate and analyze the bearing capacity of the foundation compared to the results of PDA. The method used is the Schmertmann & Nottingham method as well as the Mayerhoff method. The results of this study are carrying capacity using the Schmertmann & Nottingham method based on the results of the sondir test at the S1 point obtained a result of 804.15 tons, at the S2 sondir point the result was 761.99 tons, the S3 sondir point was 823.45 tons and at the S4 sondir point of 841.68 tons. The carrying capacity using the Meyerhoff method based on the results of the sondir test at the S1 point obtained a result of 572.39 tons, the S2 sondir point was 568.93 tons, the S3 sondir point was 568.84, and the S4 sondir point was 562.4 tons. The largest ultimate bearing capacity (Qu) value is obtained from the Schmertmann & Nottingham method at the sondir point S4, The smallest ultimate bearing capacity (Qu) value is obtained from the Meyerhoff method at the sondir point S4. The calculation results that show the least difference and are closest to the PDA are using the Meyerhoff method at the S4 sondir point and the BP-109 PDA with a difference of 115.5 tons. The Schmertmann & Nottingham method shows much greater results than PDA calculations

Interdiciplinary Journal and Hummanity (INJURITY)Vol. 4(8)
Universitas Swadaya Gunung Jati (ID)
Openalex Percentile: Top 80%
Geotechnical and construction materials studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Borepile Foundation Bearing Capacity in Building Construction Projects with Pile Driving Analyzer Test — Flavia Aurelia Hidayat, Muhammad Hafizh Prasetyo, et al. · Interdiciplinary Journal and Hummanity (INJURITY) (2025) | TGRS Research Map | TGRS