Effectiveness of Fourier, Wiener, Bilateral, and CLAHE Denoising Methods for CT Scan Image Noise Reduction

The proper reduction of noise inside CTscan Images remains crucial to achieve both better diagnosis results and clinical choices. This research analyzes through quantitative metrics the effectiveness of four popular noise reduction methods which include Fourier-based denoising and Wiener filtering as well as bilateral filtering and Contrast Limited Adaptive Histogram Equalization (CLAHE) applied to more than 500 CTscan Images. The investigated methods were assessed quantitatively through Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) while Mean Squared Error (MSE) served as the additional metric for evaluation. The evaluated denoising methods revealed bilateral filtering as the best technique based on its 50.37 dB PSNR and 0.9940 SSIM together with its 0.5967 MSE. Denoising with Fourier-based methods succeeded in removing high-frequency noise however it produced PSNR of 25.89 dB along with SSIM of 0.8138 while maintaining MSE at 167.4976 indicating lost crucial Image information. The performance balance of Wiener filtering resulted in 40.87 dB PSNR and 0.9809 SSIM and 5.3270 MSE that outperformed Fourier denoising in SSIM yet demonstrated higher MSE. CLAHE produces poor denoising outcomes because it achieves the lowest PSNR of 21.51 dB together with SSIM of 0.5707, and the maximum MSE of 459.1894 while creating undesirable artifacts. This research stands out through a full evaluation of four denoising techniques on a big dataset to create more precise analysis than prior research. The research results show bilateral filtering to be the most reliable technique for CTscan Image noise reduction when maintaining picture quality and thus represents a suitable choice for clinical use. This research adds new information to medical imaging research about quality enhancement which directly benefits clinical diagnostics and therapeutic planning.

Authors

Institutions

Publication Details

Journal
Scientific Journal of Engineering Research
Published
2025-06-17
DOI
https://doi.org/10.64539/sjer.v1i3.2025.27
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effectiveness of Fourier, Wiener, Bilateral, and CLAHE Denoising Methods for CT Scan Image Noise Reduction

Mst Jannatul Kobra, Md Owahedur Rahman, Arman Mohammad Nakib, Peter Mweetwa
1 citations
Scientific Journal of Engineering Research
Advanced X-ray and CT Imaging
0.67
article

Effectiveness of Fourier, Wiener, Bilateral, and CLAHE Denoising Methods for CT Scan Image Noise Reduction

Mst Jannatul Kobra, Md Owahedur Rahman, Arman Mohammad Nakib, Peter Mweetwa
article en
1 citations

Abstract

The proper reduction of noise inside CTscan Images remains crucial to achieve both better diagnosis results and clinical choices. This research analyzes through quantitative metrics the effectiveness of four popular noise reduction methods which include Fourier-based denoising and Wiener filtering as well as bilateral filtering and Contrast Limited Adaptive Histogram Equalization (CLAHE) applied to more than 500 CTscan Images. The investigated methods were assessed quantitatively through Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) while Mean Squared Error (MSE) served as the additional metric for evaluation. The evaluated denoising methods revealed bilateral filtering as the best technique based on its 50.37 dB PSNR and 0.9940 SSIM together with its 0.5967 MSE. Denoising with Fourier-based methods succeeded in removing high-frequency noise however it produced PSNR of 25.89 dB along with SSIM of 0.8138 while maintaining MSE at 167.4976 indicating lost crucial Image information. The performance balance of Wiener filtering resulted in 40.87 dB PSNR and 0.9809 SSIM and 5.3270 MSE that outperformed Fourier denoising in SSIM yet demonstrated higher MSE. CLAHE produces poor denoising outcomes because it achieves the lowest PSNR of 21.51 dB together with SSIM of 0.5707, and the maximum MSE of 459.1894 while creating undesirable artifacts. This research stands out through a full evaluation of four denoising techniques on a big dataset to create more precise analysis than prior research. The research results show bilateral filtering to be the most reliable technique for CTscan Image noise reduction when maintaining picture quality and thus represents a suitable choice for clinical use. This research adds new information to medical imaging research about quality enhancement which directly benefits clinical diagnostics and therapeutic planning.

Scientific Journal of Engineering ResearchVol. 1(3)
Nanjing University of Information Science and Technology (CN), Artificial Intelligence in Medicine (Canada) (CA)
Openalex Percentile: Top 28%
Advanced X-ray and CT Imaging
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.