Retrospective self-gating for single-petal rosette trajectory in 2D lung imaging

Purpose To investigate the performance of retrospective self-gating techniques in combination with the single-petal rosette (SPR) trajectory for 2D imaging of the lung. Methods Eight healthy volunteers underwent free-breathing and breath-hold MRI using the single-petal rosette trajectory (SPR), as well as radial UTE acquisition combined with the tiny golden angle acquisition scheme. Retrospective self-gating techniques (k-space based, image based and nuSG) were used for reconstruction with temporal resolutions of 50, 75 and 100 ms. The SPR trajectory was compared with the conventional radial UTE technique regarding image sharpness and signal-to-noise ratio (SNR) for all investigated resolutions. Results Low-spatial high-temporal resolution images used for image-based self-gating techniques benefit from more the efficient k-space sampling pattern of SPR. Image sharpness values are lower for SPR compared with radial UTE for all temporal resolutions but especially prominent for 75 ms temporal resolution. The same was found for SNR, where the highest increase was found for a temporal resolution of 75 ms. Conclusion Exploiting the higher efficiency in k-space sampling of the full-petal SPR for image based self-gating can be a means of decreasing temporal resolution.

Authors

Institutions

Publication Details

Journal
Frontiers in Physics
Published
2025-07-25
DOI
https://doi.org/10.3389/fphy.2025.1611544
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrospective self-gating for single-petal rosette trajectory in 2D lung imaging

Hanna Frantz, Volker Rasche
Frontiers in Physics
Advanced MRI Techniques and Applications
article

Retrospective self-gating for single-petal rosette trajectory in 2D lung imaging

Hanna Frantz, Volker Rasche
article en

Abstract

Purpose To investigate the performance of retrospective self-gating techniques in combination with the single-petal rosette (SPR) trajectory for 2D imaging of the lung. Methods Eight healthy volunteers underwent free-breathing and breath-hold MRI using the single-petal rosette trajectory (SPR), as well as radial UTE acquisition combined with the tiny golden angle acquisition scheme. Retrospective self-gating techniques (k-space based, image based and nuSG) were used for reconstruction with temporal resolutions of 50, 75 and 100 ms. The SPR trajectory was compared with the conventional radial UTE technique regarding image sharpness and signal-to-noise ratio (SNR) for all investigated resolutions. Results Low-spatial high-temporal resolution images used for image-based self-gating techniques benefit from more the efficient k-space sampling pattern of SPR. Image sharpness values are lower for SPR compared with radial UTE for all temporal resolutions but especially prominent for 75 ms temporal resolution. The same was found for SNR, where the highest increase was found for a temporal resolution of 75 ms. Conclusion Exploiting the higher efficiency in k-space sampling of the full-petal SPR for image based self-gating can be a means of decreasing temporal resolution.

Frontiers in PhysicsVol. 13
Universität Ulm (DE)
Openalex Percentile: Top 72%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retrospective self-gating for single-petal rosette trajectory in 2D lung imaging — Hanna Frantz, Volker Rasche · Frontiers in Physics (2025) | TGRS Research Map | TGRS