Reliability of the Five-Position Bell Curve Test Comparing the BTE Tech PrimusRS to the Jamar Dynamometer

Purpose: This study examines the test-retest reliability and concurrent validity of the Five-Position Bell Curve Test using the BTE PrimusRS, comparing its performance to the Jamar dynamometer. Given the critical role of grip strength in occupational health and rehabilitation, ensuring the validity of assessment tools is essential for clinical decision-making and functional evaluations. Methods: A total of 61 adults with no upper extremity pathology (27 males, 34 females) completed two identical testing sessions involving the Five-Position Bell Curve Test on both devices. Testing followed ASHT grip strength protocols, with randomized instrument order and standardized posture, grip technique, and rest periods. Intraclass correlation coefficients (ICC) and paired t-tests assessed measurement consistency across all five fret positions for both hands. Results: ICC values were near-identical (≥0.999 - 1.000) across all fret positions, indicating excellent test-retest reliability and concurrent validity between instruments. Only one statistically significant difference was observed (Fret 1, Left Hand: t(33) = 2.073, p = 0.046, d = 0.361), suggesting a minor measurement deviation. Overall, grip strength measurements between BTE PrimusRS and Jamar dynamometer were highly comparable, supporting their interchangeability for clinical assessments. Conclusion: The BTE PrimusRS demonstrates excellent test-retest reliability and concurrent validity in performing the Five- Position Bell Curve Test, aligning with the measurement validity of the Jamar dynamometer. While results confirm its clinical applicability, future research should explore its reliability in populations with upper extremity injuries and neurological impairments.

Authors

Publication Details

Journal
Journal of Rehabilitation Practices and Research
Published
2025-01-01
DOI
https://doi.org/10.33790/jrpr1100175
Primary Topic
Scientific Measurement and Uncertainty Evaluation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of the Five-Position Bell Curve Test Comparing the BTE Tech PrimusRS to the Jamar Dynamometer

Verónica Martínez Ferreras, Edwin Myers, Kaylee A. Alvarez
1 links
Journal of Rehabilitation Practices and Research
Scientific Measurement and Uncertainty Evaluation
article

Reliability of the Five-Position Bell Curve Test Comparing the BTE Tech PrimusRS to the Jamar Dynamometer

Verónica Martínez Ferreras, Edwin Myers, Kaylee A. Alvarez
article en

Abstract

Purpose: This study examines the test-retest reliability and concurrent validity of the Five-Position Bell Curve Test using the BTE PrimusRS, comparing its performance to the Jamar dynamometer. Given the critical role of grip strength in occupational health and rehabilitation, ensuring the validity of assessment tools is essential for clinical decision-making and functional evaluations. Methods: A total of 61 adults with no upper extremity pathology (27 males, 34 females) completed two identical testing sessions involving the Five-Position Bell Curve Test on both devices. Testing followed ASHT grip strength protocols, with randomized instrument order and standardized posture, grip technique, and rest periods. Intraclass correlation coefficients (ICC) and paired t-tests assessed measurement consistency across all five fret positions for both hands. Results: ICC values were near-identical (≥0.999 - 1.000) across all fret positions, indicating excellent test-retest reliability and concurrent validity between instruments. Only one statistically significant difference was observed (Fret 1, Left Hand: t(33) = 2.073, p = 0.046, d = 0.361), suggesting a minor measurement deviation. Overall, grip strength measurements between BTE PrimusRS and Jamar dynamometer were highly comparable, supporting their interchangeability for clinical assessments. Conclusion: The BTE PrimusRS demonstrates excellent test-retest reliability and concurrent validity in performing the Five- Position Bell Curve Test, aligning with the measurement validity of the Jamar dynamometer. While results confirm its clinical applicability, future research should explore its reliability in populations with upper extremity injuries and neurological impairments.

Journal of Rehabilitation Practices and ResearchVol. 6(1)
Openalex Percentile: Top 81%
Scientific Measurement and Uncertainty Evaluation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Reliability of the Five-Position Bell Curve Test Comparing the BTE Tech PrimusRS to the Jamar Dynamometer — Verónica Martínez Ferreras, Edwin Myers, et al. · Journal of Rehabilitation Practices and Research (2025) | TGRS Research Map | TGRS