Electrical Resistance Tomography (ERT) Proves a Reliable Process Analytical Technology (PAT) for Real-Time Monitoring of Solid-Liquid Suspension and Deposition in Pharmaceutical Processing

Abstract Introduction Aluminum-based adjuvants are widely utilized in vaccines; however, they present specific processing challenges due to their tendency to sediment, necessitating thorough mixing and resuspension to ensure homogeneity. Materials and methods This study investigates the use of Electrical Resistance Tomography (ERT) as a non-invasive monitoring technique for solid-liquid suspensions, overcoming the limitations of optical methods in opaque systems. A laboratory-scale stirred tank was used to analyze the resuspension behavior of hydrous magnesium silicate, which was selected as a mimic solid due to its similar density and particle size distribution to aluminum hydroxide. Discussion ERT measurements using multiple circular electrode probes demonstrated reliable quantitative detection of solid volume fractions above 5% v/v, consistent with previous research. Below this threshold, only qualitative analysis is reliable at the cost of quantitative accuracy. Notably, in the fully settled state, an unexpected increase in conductivity was observed in the lower electrode planes, suggesting that electrode-solid interactions affected the reconstructed conductivity field. This hypothesis was further validated through experiments with glass beads, where coverage of specific electrodes led to similar conductivity artefacts. Conclusions The implementation of a linear probe markedly improved the detection of deposited solids at low overall volume fractions but elevated local concentrations, demonstrating a clear correlation between electrode surface coverage and conductivity signal saturation. These findings confirm the viability of ERT for real-time suspension monitoring, demonstrating its potential for detecting solid accumulation and optimizing mixing in industrial and pharmaceutical processes, including vaccine manufacturing.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical Innovation
Published
2025-07-25
DOI
https://doi.org/10.1007/s12247-025-10054-z
Primary Topic
Electrical and Bioimpedance Tomography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrical Resistance Tomography (ERT) Proves a Reliable Process Analytical Technology (PAT) for Real-Time Monitoring of Solid-Liquid Suspension and Deposition in Pharmaceutical Processing

Alessandro Paglianti, Federico Alberini, Carlo Pergola, Giuseppina Montante et al.
Journal of Pharmaceutical Innovation
Electrical and Bioimpedance Tomography
article

Electrical Resistance Tomography (ERT) Proves a Reliable Process Analytical Technology (PAT) for Real-Time Monitoring of Solid-Liquid Suspension and Deposition in Pharmaceutical Processing

Alessandro Paglianti, Federico Alberini, Carlo Pergola, Giuseppina Montante, Andrea Albano, Riccardo Pellicari
article en

Abstract

Abstract Introduction Aluminum-based adjuvants are widely utilized in vaccines; however, they present specific processing challenges due to their tendency to sediment, necessitating thorough mixing and resuspension to ensure homogeneity. Materials and methods This study investigates the use of Electrical Resistance Tomography (ERT) as a non-invasive monitoring technique for solid-liquid suspensions, overcoming the limitations of optical methods in opaque systems. A laboratory-scale stirred tank was used to analyze the resuspension behavior of hydrous magnesium silicate, which was selected as a mimic solid due to its similar density and particle size distribution to aluminum hydroxide. Discussion ERT measurements using multiple circular electrode probes demonstrated reliable quantitative detection of solid volume fractions above 5% v/v, consistent with previous research. Below this threshold, only qualitative analysis is reliable at the cost of quantitative accuracy. Notably, in the fully settled state, an unexpected increase in conductivity was observed in the lower electrode planes, suggesting that electrode-solid interactions affected the reconstructed conductivity field. This hypothesis was further validated through experiments with glass beads, where coverage of specific electrodes led to similar conductivity artefacts. Conclusions The implementation of a linear probe markedly improved the detection of deposited solids at low overall volume fractions but elevated local concentrations, demonstrating a clear correlation between electrode surface coverage and conductivity signal saturation. These findings confirm the viability of ERT for real-time suspension monitoring, demonstrating its potential for detecting solid accumulation and optimizing mixing in industrial and pharmaceutical processes, including vaccine manufacturing.

Journal of Pharmaceutical InnovationVol. 20(4)
GlaxoSmithKline (United Kingdom) (GB), GlaxoSmithKline (Italy) (IT), University of Bologna (IT)
Openalex Percentile: Top 82%
Electrical and Bioimpedance Tomography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.