Determination of Trace 55Fe and 63Ni in Steel Samples via Liquid Scintillation Counting

In the decommissioning of nuclear facilities, activated steel often contains radionuclides such as 55Fe and 63Ni, which are categorized as hard-to-measure due to their emission of only low-energy beta particles or X-rays. In samples exhibiting very low radioactivity, close to background levels, a large quantity of steel must undergo extensive physical and chemical processing to achieve the Minimum Detectable Activity Concentration (MDC) necessary for clearance, recycling, or reuse. Italian regulations set particularly stringent clearance levels for these radionuclides (1 Bq/g for both 55Fe and 63Ni), significantly lower than those specified in the EU Directive 2013/59 (1000 Bq/g for 55Fe and 100 Bq/g for 63Ni). Additionally, Italian authorities may enforce even stricter limits depending on specific circumstances. The analytical challenge is compounded by the presence of large amounts of non-radioactive Fe and Ni, which can cause color quenching, further extending analysis times. This study presents a reliable and optimized method for the quantitative determination of 55Fe and 63Ni in steel samples with activity levels approaching regulatory thresholds. The methodology was specifically developed and applied to steel from the Frascati Tokamak Upgrade (FTU) facility, under decommissioning by ENEA. The optimization process demonstrated that achieving the required MDCs necessitates acquisition times of approximately 5 days for 55Fe and 6 h for 63Ni, ensuring compliance with stringent regulatory requirements and supporting efficient laboratory workflows.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-07-25
DOI
https://doi.org/10.3390/app15158264
Citations
1
Primary Topic
Radioactive contamination and transfer
Type
article
Field-Weighted Citation Impact
1.11
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of Trace 55Fe and 63Ni in Steel Samples via Liquid Scintillation Counting

M.L. Cozzella, Tiziana Guarcini, Giada Gandolfo, G. A. Marzo
1 citations
Applied Sciences
Radioactive contamination and transfer
1.11
article

Determination of Trace 55Fe and 63Ni in Steel Samples via Liquid Scintillation Counting

M.L. Cozzella, Tiziana Guarcini, Giada Gandolfo, G. A. Marzo
article en
1 citations

Abstract

In the decommissioning of nuclear facilities, activated steel often contains radionuclides such as 55Fe and 63Ni, which are categorized as hard-to-measure due to their emission of only low-energy beta particles or X-rays. In samples exhibiting very low radioactivity, close to background levels, a large quantity of steel must undergo extensive physical and chemical processing to achieve the Minimum Detectable Activity Concentration (MDC) necessary for clearance, recycling, or reuse. Italian regulations set particularly stringent clearance levels for these radionuclides (1 Bq/g for both 55Fe and 63Ni), significantly lower than those specified in the EU Directive 2013/59 (1000 Bq/g for 55Fe and 100 Bq/g for 63Ni). Additionally, Italian authorities may enforce even stricter limits depending on specific circumstances. The analytical challenge is compounded by the presence of large amounts of non-radioactive Fe and Ni, which can cause color quenching, further extending analysis times. This study presents a reliable and optimized method for the quantitative determination of 55Fe and 63Ni in steel samples with activity levels approaching regulatory thresholds. The methodology was specifically developed and applied to steel from the Frascati Tokamak Upgrade (FTU) facility, under decommissioning by ENEA. The optimization process demonstrated that achieving the required MDCs necessitates acquisition times of approximately 5 days for 55Fe and 6 h for 63Ni, ensuring compliance with stringent regulatory requirements and supporting efficient laboratory workflows.

Applied SciencesVol. 15(15)
National Agency for New Technologies Energy and Sustainable Economic Development (GB)
Openalex Percentile: Top 21%
Radioactive contamination and transfer
1.11
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Determination of Trace 55Fe and 63Ni in Steel Samples via Liquid Scintillation Counting — M.L. Cozzella, Tiziana Guarcini, et al. · Applied Sciences (2025) | TGRS Research Map | TGRS