Optical measurement of refractive index gradients with position-sensitive detectors

This study proposes a PSD-based method for refractive index gradient measurement with advantages of miniaturization and real-time capability. By integrating laser beam deflection principles with PSD detection, we establish a theoretical model correlating spot displacement with refractive index gradients and construct a measurement system achieving 2.22 × 10 −5 refractive index unit (RIU)/m resolution. Theoretical analysis addresses beam deviation caused by collimation misalignment (θ 0 ), proposing an improved method. Ray-tracing simulations demonstrate significantly relaxed collimation requirements: displacement resolution reaches 1μm when |θ 0 |<1.3°. Validation using stratified saline solutions shows integrated PSD gradient measurements agree with refractometer (PRM-2000α) data within <1 × 10 −5 RIU error.

Authors

Institutions

Publication Details

Journal
Optics Continuum
Published
2025-07-25
DOI
https://doi.org/10.1364/optcon.569278
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical measurement of refractive index gradients with position-sensitive detectors

Liyan Li, Yongjie Wang, Bo Wei, Qi Wang et al.
Optics Continuum
Advanced Measurement and Metrology Techniques
article

Optical measurement of refractive index gradients with position-sensitive detectors

Liyan Li, Yongjie Wang, Bo Wei, Qi Wang, Jianyong Zhang, Yan Zhou
article en

Abstract

This study proposes a PSD-based method for refractive index gradient measurement with advantages of miniaturization and real-time capability. By integrating laser beam deflection principles with PSD detection, we establish a theoretical model correlating spot displacement with refractive index gradients and construct a measurement system achieving 2.22 × 10 −5 refractive index unit (RIU)/m resolution. Theoretical analysis addresses beam deviation caused by collimation misalignment (θ 0 ), proposing an improved method. Ray-tracing simulations demonstrate significantly relaxed collimation requirements: displacement resolution reaches 1μm when |θ 0 |<1.3°. Validation using stratified saline solutions shows integrated PSD gradient measurements agree with refractometer (PRM-2000α) data within <1 × 10 −5 RIU error.

Optics ContinuumVol. 4(8)
Institute of Semiconductors (CN)
Affordable and clean energy
Openalex Percentile: Top 81%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.