Atomic density disturbance rejection in atomic gyroscopes via faraday polarimetric decoupling

Atomic spin gyroscopes are promising candidates for next-generation inertial navigation due to extremely high theoretical precision, relatively small size among atomic gyroscopes, and promising potential for miniaturization. In particular, the spin-exchange relaxation-free (SERF) atomic gyroscope relies on optical pumping to polarize atoms, enabling rotation sensing through the Faraday optical rotation angle (FORA). However, fluctuations in atomic density introduce systematic errors in FORA measurements, limiting long-term stability. We present a data-driven decoupling method that isolates atomic density fluctuations from the FORA signal by modeling spatially resolved light absorption in the vapor cell. The model accounts for the spatial distribution of spin polarization in the pump-light interaction volume, density-dependent relaxation rates, wall-induced relaxation, and polarization diffusion, and is implemented within a finite-element framework. Compared to the conventional Lambert-Beer law, which assumes one-dimensional homogeneity, our approach captures the full three-dimensional density and polarization distribution, significantly improving the accuracy of light absorption modeling. The resulting absorption-density maps are used to train a feedforward neural network, yielding a high-precision estimator for atomic density fluctuations. This estimator enables the construction of a decoupling equation that separates the density contribution from the FORA signal. Experimental validation shows that this method improves the bias instability at σ (100 s) of the gyroscope was improved by 73.1% compared to traditional platinum-resistance-based stabilization. The proposed framework is general and can be extended to other optical pumping-based sensors, such as optically pumped magnetometers.

Authors

Institutions

Publication Details

Journal
Defence Technology
Published
2025-07-25
DOI
https://doi.org/10.1016/j.dt.2025.07.022
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Atomic density disturbance rejection in atomic gyroscopes via faraday polarimetric decoupling

Zhuo Wang, Xusheng Lei, Xinhui Liu, Haoying Pang et al.
Defence Technology
Atomic and Subatomic Physics Research
article

Atomic density disturbance rejection in atomic gyroscopes via faraday polarimetric decoupling

Zhuo Wang, Xusheng Lei, Xinhui Liu, Haoying Pang, Jixi Lu, Zehua Liu, Yifan Yan, Wei Quan
article en

Abstract

Atomic spin gyroscopes are promising candidates for next-generation inertial navigation due to extremely high theoretical precision, relatively small size among atomic gyroscopes, and promising potential for miniaturization. In particular, the spin-exchange relaxation-free (SERF) atomic gyroscope relies on optical pumping to polarize atoms, enabling rotation sensing through the Faraday optical rotation angle (FORA). However, fluctuations in atomic density introduce systematic errors in FORA measurements, limiting long-term stability. We present a data-driven decoupling method that isolates atomic density fluctuations from the FORA signal by modeling spatially resolved light absorption in the vapor cell. The model accounts for the spatial distribution of spin polarization in the pump-light interaction volume, density-dependent relaxation rates, wall-induced relaxation, and polarization diffusion, and is implemented within a finite-element framework. Compared to the conventional Lambert-Beer law, which assumes one-dimensional homogeneity, our approach captures the full three-dimensional density and polarization distribution, significantly improving the accuracy of light absorption modeling. The resulting absorption-density maps are used to train a feedforward neural network, yielding a high-precision estimator for atomic density fluctuations. This estimator enables the construction of a decoupling equation that separates the density contribution from the FORA signal. Experimental validation shows that this method improves the bias instability at σ (100 s) of the gyroscope was improved by 73.1% compared to traditional platinum-resistance-based stabilization. The proposed framework is general and can be extended to other optical pumping-based sensors, such as optically pumped magnetometers.

Defence TechnologyVol. 55
Hefei University (CN), Beihang University (CN)
Beihang University, Natural Science Foundation of Beijing Municipality
Affordable and clean energy
Openalex Percentile: Top 86%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.