Development and exergy analysis of a newly designed tower-solar collector-based combined cooling-desalination system
This study focuses on the proposal and analysis of a new solar tower-based cogeneration system where reverse osmosis (RO) unit is connected to Kalina cycle which combines internally with absorption refrigeration cycle (ARC) aiming to produce cooling and fresh water, simultaneously. System modelling was done in EES software based on mass, energy, and exergy equations. Analysis of the results revealed that cogeneration plant yield efficiencies of 44.54% energetically and 25.81% exergetically. The results further indicated that 23.14% of the total exergy destruction occurs in central receiver. The results provide important inferences about the exergetic performance of solar-based cooling-desalination cycle.
Authors
- Tawfiq Al‐Mughanam (ORCID: https://orcid.org/0000-0002-9768-7800)
Institutions
- King Faisal University (SA)
Publication Details
- Journal
- International Journal of Exergy
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1504/ijex.2025.147646
- Primary Topic
- Solar-Powered Water Purification Methods
- Type
- article
- Field-Weighted Citation Impact
- 0.00