Evaluation of detection efficiency of a transition edge sensor at C-band wavelength

Photon-number-resolving detectors face strict demands regarding detection efficiency to meet the needs of quantum information processing. We constructed a system that can accurately evaluate system detection efficiency of a photon-number-resolving detector. We generated an optical pulse containing an arbitrary number of photons for the initial states by attenuated laser light; this pulse was used to evaluate the detection efficiency of the device under test. To generate this pulse, we modulated a continuous wavelength tunable laser using an acoustic optical modulator. From the photon statistics of the initial states, we found a second-order correlation function that was almost 1 at any wavelength, and these photon statistics followed a Poisson distribution. For the device under test, we evaluated the detection efficiency of a transition edge sensor and we employed two methods to calculate the number of detected photons. This value was calculated based on each photon state (method 1) or based on the zero photon state by assuming a Poisson distribution (method 2). Although the results of both methods were comparable within the range of uncertainty, method 2 yielded smaller uncertainty than method 1. We found that the wavelength-dependent detection efficiency was explained by the photon absorptance characteristics of the device under test. Additionally, the system detection efficiency varied from approximately 87 % to 93 %, and the expanded uncertainty values of methods 1 and 2 were 4.1 % and 1.5 %, respectively. This system enables the accurate evaluation of quantum states of photons at various wavelengths. • We developed a calibration system for the C-band wavelength using laser pulses. • Initial states were generated via laser by switching acoustic optical module. • Input state photon statistics were evaluated by a second-order correlation function. • Wavelength-dependent detection efficiency was precisely determined. • Detection efficiency was evaluated by comparing experimental and simulation values.

Authors

Institutions

Publication Details

Journal
Optics & Laser Technology
Published
2025-07-25
DOI
https://doi.org/10.1016/j.optlastec.2025.113414
Citations
2
Primary Topic
Photonic and Optical Devices
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of detection efficiency of a transition edge sensor at C-band wavelength

Daiji Fukuda, Tetsuya Tsuruta, M. Rajteri, Takeshi Jodoi
2 citations
Optics & Laser Technology
Photonic and Optical Devices
1.46
article

Evaluation of detection efficiency of a transition edge sensor at C-band wavelength

Daiji Fukuda, Tetsuya Tsuruta, M. Rajteri, Takeshi Jodoi
article en
2 citations

Abstract

Photon-number-resolving detectors face strict demands regarding detection efficiency to meet the needs of quantum information processing. We constructed a system that can accurately evaluate system detection efficiency of a photon-number-resolving detector. We generated an optical pulse containing an arbitrary number of photons for the initial states by attenuated laser light; this pulse was used to evaluate the detection efficiency of the device under test. To generate this pulse, we modulated a continuous wavelength tunable laser using an acoustic optical modulator. From the photon statistics of the initial states, we found a second-order correlation function that was almost 1 at any wavelength, and these photon statistics followed a Poisson distribution. For the device under test, we evaluated the detection efficiency of a transition edge sensor and we employed two methods to calculate the number of detected photons. This value was calculated based on each photon state (method 1) or based on the zero photon state by assuming a Poisson distribution (method 2). Although the results of both methods were comparable within the range of uncertainty, method 2 yielded smaller uncertainty than method 1. We found that the wavelength-dependent detection efficiency was explained by the photon absorptance characteristics of the device under test. Additionally, the system detection efficiency varied from approximately 87 % to 93 %, and the expanded uncertainty values of methods 1 and 2 were 4.1 % and 1.5 %, respectively. This system enables the accurate evaluation of quantum states of photons at various wavelengths. • We developed a calibration system for the C-band wavelength using laser pulses. • Initial states were generated via laser by switching acoustic optical module. • Input state photon statistics were evaluated by a second-order correlation function. • Wavelength-dependent detection efficiency was precisely determined. • Detection efficiency was evaluated by comparing experimental and simulation values.

Optics & Laser TechnologyVol. 192
Bunkyo University (JP), Istituto Nazionale di Ricerca Metrologica (IT), National Institute of Advanced Industrial Science and Technology (JP), The University of Tokyo (JP)
Moonshot Research and Development Program
Affordable and clean energy
Openalex Percentile: Top 16%
Photonic and Optical Devices
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.