Oscillation Mechanism of SRF-PLL in Wind Power Systems Under Voltage Sags and Improper Control Parameters

The synchronous reference frame phase-locked loop (SRF-PLL) is widely employed for grid synchronization in wind farms. However, it may exhibit oscillations under voltage sags or improper parameter settings. These oscillations may compromise the secure integration of large-scale wind power. Therefore, mitigating the oscillations of the SRF-PLL is crucial for ensuring stable and reliable operation. To this end, this paper investigates the underlying oscillation mechanism of the SRF-PLL from local and global perspectives. By taking into account the grid voltage and control parameters, it is revealed that oscillations of the SRF-PLL can be triggered by grid voltage sags and/or the improper control parameters. More specifically, from the local perspective, the SRF-PLL exhibits distinct qualitative behaviors around its stable equilibrium points under different grid voltage amplitudes. As a result, when grid voltage sags occur, the SRF-PLL may exhibit multiple oscillation modes and experience a prolonged transient response. Furthermore, from the global viewpoint, the large-signal analysis reveals that the SRF-PLL has infinitely many asymmetrical convergence regions. However, the sizes of these asymmetrical convergence regions shrink significantly under low grid voltage amplitude and/or small control parameters. In this case, even if the parameters in the small-signal model of the SRF-PLL are well-designed, a small disturbance can shift the operating point into other regions, resulting in undesirable oscillations and a sluggish dynamic response. The validity of the theoretical analysis is further supported by experimental verification.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-08-03
DOI
https://doi.org/10.3390/electronics14153100
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oscillation Mechanism of SRF-PLL in Wind Power Systems Under Voltage Sags and Improper Control Parameters

Zhiyong Dai, Qitao Sun, Jinke Ma, Shuaishuai Lv et al.
Electronics
Microgrid Control and Optimization
article

Oscillation Mechanism of SRF-PLL in Wind Power Systems Under Voltage Sags and Improper Control Parameters

Zhiyong Dai, Qitao Sun, Jinke Ma, Shuaishuai Lv, Ning Lü, Guoqing Wang
article en

Abstract

The synchronous reference frame phase-locked loop (SRF-PLL) is widely employed for grid synchronization in wind farms. However, it may exhibit oscillations under voltage sags or improper parameter settings. These oscillations may compromise the secure integration of large-scale wind power. Therefore, mitigating the oscillations of the SRF-PLL is crucial for ensuring stable and reliable operation. To this end, this paper investigates the underlying oscillation mechanism of the SRF-PLL from local and global perspectives. By taking into account the grid voltage and control parameters, it is revealed that oscillations of the SRF-PLL can be triggered by grid voltage sags and/or the improper control parameters. More specifically, from the local perspective, the SRF-PLL exhibits distinct qualitative behaviors around its stable equilibrium points under different grid voltage amplitudes. As a result, when grid voltage sags occur, the SRF-PLL may exhibit multiple oscillation modes and experience a prolonged transient response. Furthermore, from the global viewpoint, the large-signal analysis reveals that the SRF-PLL has infinitely many asymmetrical convergence regions. However, the sizes of these asymmetrical convergence regions shrink significantly under low grid voltage amplitude and/or small control parameters. In this case, even if the parameters in the small-signal model of the SRF-PLL are well-designed, a small disturbance can shift the operating point into other regions, resulting in undesirable oscillations and a sluggish dynamic response. The validity of the theoretical analysis is further supported by experimental verification.

ElectronicsVol. 14(15)
Xidian University (CN), Hangzhou Dianzi University (CN)
National Key Research and Development Program of China
Openalex Percentile: Top 78%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.