Double QRS Transition Due to Anodal Capture During Left Bundle Branch Area Pacing: A Case Report

Anodal capture, characterized by a different QRS morphology compared to cathodal capture, is a well-known issue in cardiac resynchronization therapy (CRT). Left bundle branch area pacing (LBBAP), a novel physiological pacing technique, is also used as a bailout strategy following failed conventional CRT implantation. In LBBAP, QRS transition, defined by a change in paced QRS morphology, serves as a key marker of successful lead placement. This case report is the first to document both high-output anodal capture and LBBAP-induced QRS transition in a single individual receiving LBBAP with an implantable cardioverter-defibrillator (ICD) as a bailout strategy for failed cardiac resynchronization therapy with defibrillator (CRT-D) implantation. Their coexistence underscores unique device optimization challenges in this emerging approach.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Development and Disease
Published
2025-08-03
DOI
https://doi.org/10.3390/jcdd12080299
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Double QRS Transition Due to Anodal Capture During Left Bundle Branch Area Pacing: A Case Report

Luca Canovi, Matteo Bertini, Francesco Vitali, Angelo Melpignano et al.
Journal of Cardiovascular Development and Disease
Cardiac pacing and defibrillation studies
article

Double QRS Transition Due to Anodal Capture During Left Bundle Branch Area Pacing: A Case Report

Luca Canovi, Matteo Bertini, Francesco Vitali, Angelo Melpignano, L Vocale, Jacopo Bonini
article en

Abstract

Anodal capture, characterized by a different QRS morphology compared to cathodal capture, is a well-known issue in cardiac resynchronization therapy (CRT). Left bundle branch area pacing (LBBAP), a novel physiological pacing technique, is also used as a bailout strategy following failed conventional CRT implantation. In LBBAP, QRS transition, defined by a change in paced QRS morphology, serves as a key marker of successful lead placement. This case report is the first to document both high-output anodal capture and LBBAP-induced QRS transition in a single individual receiving LBBAP with an implantable cardioverter-defibrillator (ICD) as a bailout strategy for failed cardiac resynchronization therapy with defibrillator (CRT-D) implantation. Their coexistence underscores unique device optimization challenges in this emerging approach.

Journal of Cardiovascular Development and DiseaseVol. 12(8)
Arcispedale Sant'Anna (IT)
Openalex Percentile: Top 69%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.