Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative Study

Everolimus (EVE), an mTOR inhibitor, is widely used in solid organ transplantation (SOT) because of its immunosuppressive properties. Due to its narrow therapeutic window and significant pharmacokinetic variability, therapeutic drug monitoring (TDM) is essential for achieving optimal outcomes. We developed and thoroughly validated a robust LC-MS/MS method to measure EVE levels in venous whole blood (WB) and capillary blood collected using two microsampling devices: Mitra™ (volumetric absorptive microsampling, VAMS) and Capitainer<sup>®</sup> (quantitative dried blood spot, qDBS). The validation followed EMA and IATDMCT guidelines, assessing linearity (1.27-64.80 ng/mL for WB and 0.50-60 ng/mL for VAMS/qDBS), as well as selectivity, accuracy, precision, matrix effects, recovery, stability, and incurred sample reanalysis. Clinical validation involved 66 matched samples from 33 adult SOT recipients. The method demonstrated high accuracy and precision across all matrices, with no significant carryover or matrix interference. Statistical analysis using Passing-Bablok regression and Bland-Altman plots showed excellent agreement between the microsampling methods and the venous reference. Hematocrit effects were tested both in laboratory conditions and on clinical samples and were found to be negligible. This study provides the first comprehensive analytical and clinical validation of the Mitra and Capitainer devices for EVE monitoring. The validated LC-MS/MS microsampling method supports decentralized, patient-centred TDM, offering a reliable alternative to conventional blood sampling in transplant care.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-07-26
DOI
https://doi.org/10.3390/molecules30153139
Citations
1
Primary Topic
Biosimilars and Bioanalytical Methods
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative Study

Arkadiusz Kocur, Dorota Miszewska‐Szyszkowska, Katarzyna Polak, Olga Rostkowska et al.
1 citations
Molecules
Biosimilars and Bioanalytical Methods
0.80
article

Therapeutic Drug Monitoring of Everolimus Using Volumetric Absorptive Microsampling and Quantitative Dried Blood Spot Methods with LC-MS/MS in Adult Solid Organ Transplant Recipients: An Analytical and Clinical Comparative Study

Arkadiusz Kocur, Dorota Miszewska‐Szyszkowska, Katarzyna Polak, Olga Rostkowska, T. Pawiński, Magdalena Durlik, Teresa Bączkowska, K. Korniluk, Bartosz Olkowski, Mateusz Moczulski
article en
1 citations

Abstract

Everolimus (EVE), an mTOR inhibitor, is widely used in solid organ transplantation (SOT) because of its immunosuppressive properties. Due to its narrow therapeutic window and significant pharmacokinetic variability, therapeutic drug monitoring (TDM) is essential for achieving optimal outcomes. We developed and thoroughly validated a robust LC-MS/MS method to measure EVE levels in venous whole blood (WB) and capillary blood collected using two microsampling devices: Mitra™ (volumetric absorptive microsampling, VAMS) and Capitainer<sup>®</sup> (quantitative dried blood spot, qDBS). The validation followed EMA and IATDMCT guidelines, assessing linearity (1.27-64.80 ng/mL for WB and 0.50-60 ng/mL for VAMS/qDBS), as well as selectivity, accuracy, precision, matrix effects, recovery, stability, and incurred sample reanalysis. Clinical validation involved 66 matched samples from 33 adult SOT recipients. The method demonstrated high accuracy and precision across all matrices, with no significant carryover or matrix interference. Statistical analysis using Passing-Bablok regression and Bland-Altman plots showed excellent agreement between the microsampling methods and the venous reference. Hematocrit effects were tested both in laboratory conditions and on clinical samples and were found to be negligible. This study provides the first comprehensive analytical and clinical validation of the Mitra and Capitainer devices for EVE monitoring. The validated LC-MS/MS microsampling method supports decentralized, patient-centred TDM, offering a reliable alternative to conventional blood sampling in transplant care.

MoleculesVol. 30(15)
Medical University of Warsaw (PL)
Warszawski Uniwersytet Medyczny
Good health and well-being
Openalex Percentile: Top 25%
Biosimilars and Bioanalytical Methods
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.