Development and validation of a stability-indicating RP-HPLC method for tizanidine hydrochloride using DOE

Background: Tizanidine hydrochloride (TIZ) is a centrally acting α2-adrenergic receptor agonist widely prescribed for managing spasticity. Given its therapeutic importance, a reliable, stability-indicating analytical method is crucial to ensure both the quality and regulatory compliance of Tizanidine hydrochloride. Existing RP-HPLC methods often lack robustness, sensitivity, or DoE optimization, highlighting the need for an improved approach. Methodology: A stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method with stability-indicating properties was developed and validated using a Design of Experiments (DoE) approach. A full factorial design was implemented, optimizing mobile phase composition and flow rate as key method variables. Chromatographic separation was achieved using an Agilent Zorbax Bonus RP column (250 × 4.6 mm, 5 µm) with a mobile phase of 0.1% trifluoroacetic acid (TFA) and acetonitrile (65:35 v/v) at a 0.5 mL/min flow rate. Detection was performed at 228 nm. The method was validated by ICH guidelines, evaluating parameters such as specificity, precision, accuracy, linearity, robustness, and forced degradation. Results and Discussion: The method demonstrated excellent linearity (r² = 1.00) across concentration levels ranging from 80% to 120% of the target concentration. The LOD and LOQ were 1.00 µg/mL and 3.04 µg/mL, respectively. High precision (%RSD < 2%) and accuracy (99–101% recovery) were observed. Forced degradation studies revealed notable degradation under oxidative (36.08%) and acidic (15.73%) conditions. Conclusion: The developed RP-HPLC method is precise, robust, and suitable for the routine quality control and stability assessment of Tizanidine hydrochloride in pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
Journal of Applied Pharmaceutical Research
Published
2025-06-30
DOI
https://doi.org/10.69857/joapr.v13i3.1057
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and validation of a stability-indicating RP-HPLC method for tizanidine hydrochloride using DOE

Janki Patel, Prasad Gunjal
1 citations
Journal of Applied Pharmaceutical Research
Analytical Chemistry and Sensors
0.74
article

Development and validation of a stability-indicating RP-HPLC method for tizanidine hydrochloride using DOE

Janki Patel, Prasad Gunjal
article en
1 citations

Abstract

Background: Tizanidine hydrochloride (TIZ) is a centrally acting α2-adrenergic receptor agonist widely prescribed for managing spasticity. Given its therapeutic importance, a reliable, stability-indicating analytical method is crucial to ensure both the quality and regulatory compliance of Tizanidine hydrochloride. Existing RP-HPLC methods often lack robustness, sensitivity, or DoE optimization, highlighting the need for an improved approach. Methodology: A stability-indicating reverse-phase high-performance liquid chromatography (RP-HPLC) method with stability-indicating properties was developed and validated using a Design of Experiments (DoE) approach. A full factorial design was implemented, optimizing mobile phase composition and flow rate as key method variables. Chromatographic separation was achieved using an Agilent Zorbax Bonus RP column (250 × 4.6 mm, 5 µm) with a mobile phase of 0.1% trifluoroacetic acid (TFA) and acetonitrile (65:35 v/v) at a 0.5 mL/min flow rate. Detection was performed at 228 nm. The method was validated by ICH guidelines, evaluating parameters such as specificity, precision, accuracy, linearity, robustness, and forced degradation. Results and Discussion: The method demonstrated excellent linearity (r² = 1.00) across concentration levels ranging from 80% to 120% of the target concentration. The LOD and LOQ were 1.00 µg/mL and 3.04 µg/mL, respectively. High precision (%RSD < 2%) and accuracy (99–101% recovery) were observed. Forced degradation studies revealed notable degradation under oxidative (36.08%) and acidic (15.73%) conditions. Conclusion: The developed RP-HPLC method is precise, robust, and suitable for the routine quality control and stability assessment of Tizanidine hydrochloride in pharmaceutical formulations.

Journal of Applied Pharmaceutical ResearchVol. 13(3)
Parul University (IN)
Openalex Percentile: Top 29%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.