Assessing and Improving the Reproducibility of Cerebrovascular Reactivity Evaluations in Healthy Subjects Using Short-Breath-Hold fMRI

<b>Background/Objectives</b>: Cerebrovascular reactivity (CVR) is a key marker of cerebrovascular function, facilitating the early detection of neurovascular dysfunction. Breath-hold functional MRI (bh-fMRI) is a non-invasive method for assessing CVR. This study evaluates the reproducibility of bh-fMRI using short breath-hold periods, which are practical for clinical use. <b>Methods</b>: In a prospective study, 50 healthy subjects underwent three self-paced, end-expiration bh-fMRI sessions with 9 s breath-hold periods at 3T. A 30 min break between the second and third sessions was included. The reproducibility of the percentage signal change (PSC) in predefined volumes of interest for a ±0 s, ±3 s and ±6 s interval around the cerebellar peak (IAP)) was evaluated. The intraclass correlation coefficient (ICC) and the intra-personal coefficient of variation (CV<sub>intra</sub>) were calculated between the individual sessions. <b>Results</b>: This study demonstrated excellent reproducibility, with an ICC (2, k) for a ±0 s IAP across all sessions at 0.887 (95% CI: 0.882-0.892). The ICC values remained within an excellent range even when the participants left the scanner between sessions. The CV<sub>intra</sub> for the ±0 s IAP (14.54% ± 8.54%) remained below the 33% fiducial limit. A larger IAP revealed higher ICC values but higher CV<sub>intra</sub> values and lower PSC values. <b>Conclusions</b>: Bh-fMRI with 9 s breath-hold periods yields highly reproducible CVR assessments, supporting its feasibility for clinical implementation.

Authors

Publication Details

Journal
Diagnostics
Published
2025-08-03
DOI
https://doi.org/10.3390/diagnostics15151946
Citations
2
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing and Improving the Reproducibility of Cerebrovascular Reactivity Evaluations in Healthy Subjects Using Short-Breath-Hold fMRI

Till‐Karsten Hauser, Leonie Zerweck, Uwe Klose, Ulrike Ernemann et al.
2 citations
Diagnostics
Advanced MRI Techniques and Applications
2.72
article

Assessing and Improving the Reproducibility of Cerebrovascular Reactivity Evaluations in Healthy Subjects Using Short-Breath-Hold fMRI

Till‐Karsten Hauser, Leonie Zerweck, Uwe Klose, Ulrike Ernemann, Emely Renger
article en
2 citations

Abstract

<b>Background/Objectives</b>: Cerebrovascular reactivity (CVR) is a key marker of cerebrovascular function, facilitating the early detection of neurovascular dysfunction. Breath-hold functional MRI (bh-fMRI) is a non-invasive method for assessing CVR. This study evaluates the reproducibility of bh-fMRI using short breath-hold periods, which are practical for clinical use. <b>Methods</b>: In a prospective study, 50 healthy subjects underwent three self-paced, end-expiration bh-fMRI sessions with 9 s breath-hold periods at 3T. A 30 min break between the second and third sessions was included. The reproducibility of the percentage signal change (PSC) in predefined volumes of interest for a ±0 s, ±3 s and ±6 s interval around the cerebellar peak (IAP)) was evaluated. The intraclass correlation coefficient (ICC) and the intra-personal coefficient of variation (CV<sub>intra</sub>) were calculated between the individual sessions. <b>Results</b>: This study demonstrated excellent reproducibility, with an ICC (2, k) for a ±0 s IAP across all sessions at 0.887 (95% CI: 0.882-0.892). The ICC values remained within an excellent range even when the participants left the scanner between sessions. The CV<sub>intra</sub> for the ±0 s IAP (14.54% ± 8.54%) remained below the 33% fiducial limit. A larger IAP revealed higher ICC values but higher CV<sub>intra</sub> values and lower PSC values. <b>Conclusions</b>: Bh-fMRI with 9 s breath-hold periods yields highly reproducible CVR assessments, supporting its feasibility for clinical implementation.

DiagnosticsVol. 15(15)
Eberhard Karls Universität Tübingen
Good health and well-being
Openalex Percentile: Top 9%
Advanced MRI Techniques and Applications
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessing and Improving the Reproducibility of Cerebrovascular Reactivity Evaluations in Healthy Subjects Using Short-Breath-Hold fMRI — Till‐Karsten Hauser, Leonie Zerweck, et al. · Diagnostics (2025) | TGRS Research Map | TGRS