Impact of dust composition on parabolic trough concentrator performance across diverse regions

• The Monte Carlo Ray Tracing method evaluated parabolic trough concentrators' performance under dust. • A set of fitting formulas were developed for various dust compositions and deposition densities. • The most cost-effective cleaning strategies for various cleaning methods were discussed. Parabolic trough concentrators are widely utilized in solar energy for thermal conversion, owing to their simple design and high efficiency. However, their outdoor efficiency is often hindered by dust accumulation. This study employs the Monte Carlo Ray Tracing method, a computational method simulating the interaction between dust and concentrators surfaces, to investigate the effects of various dust types on the optical performance of concentrators. Dust accumulation is analyzed for four representative regions: Garz, Arizona, Qinghai, and Lahore. A comprehensive analysis of dust composition in these areas reveals key components such as SiO 2 , Al 2 O 3 , Fe 2 O 3 , C, and H 2 O, which play crucial roles in optical efficiency. Increasing low-absorption components such as SiO 2 and H 2 O in dust steeply reduces relative reflectance. Conversely, higher proportions of high-absorption components like Fe 2 O 3 and C in dust lead to a steep increase in relative reflectance. This study quantifies the impact of dust accumulation on the optical performance of concentrators using the Monte Carlo Ray Tracing method, revealing a 20.4 % and 30.5 % efficiency reduction at a deposition density of 10 and 15 g/m 2 , and highlighting the critical role of dust composition in reflectivity and absorption. Based on these findings, a fitting formula is proposed to predict performance degradation and recommend an economic cleaning cycle of 20.8 to 61.1 days, providing a basis for the optimization of concentrated solar power systems in dust-prone regions. This research enhances the deployment and maintenance of concentrated solar power systems by elucidating the impact of dust accumulation on parabolic trough concentrator performance.

Authors

Institutions

Publication Details

Journal
Solar Energy
Published
2025-08-04
DOI
https://doi.org/10.1016/j.solener.2025.113834
Citations
1
Primary Topic
Solar Thermal and Photovoltaic Systems
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of dust composition on parabolic trough concentrator performance across diverse regions

G.H. Tang, Maoquan Huang, Qie Sun, Mu Du et al.
1 citations
Solar Energy
Solar Thermal and Photovoltaic Systems
0.36
article

Impact of dust composition on parabolic trough concentrator performance across diverse regions

G.H. Tang, Maoquan Huang, Qie Sun, Mu Du, Yang Zhao, Huijuan Wang
article en
1 citations

Abstract

• The Monte Carlo Ray Tracing method evaluated parabolic trough concentrators' performance under dust. • A set of fitting formulas were developed for various dust compositions and deposition densities. • The most cost-effective cleaning strategies for various cleaning methods were discussed. Parabolic trough concentrators are widely utilized in solar energy for thermal conversion, owing to their simple design and high efficiency. However, their outdoor efficiency is often hindered by dust accumulation. This study employs the Monte Carlo Ray Tracing method, a computational method simulating the interaction between dust and concentrators surfaces, to investigate the effects of various dust types on the optical performance of concentrators. Dust accumulation is analyzed for four representative regions: Garz, Arizona, Qinghai, and Lahore. A comprehensive analysis of dust composition in these areas reveals key components such as SiO 2 , Al 2 O 3 , Fe 2 O 3 , C, and H 2 O, which play crucial roles in optical efficiency. Increasing low-absorption components such as SiO 2 and H 2 O in dust steeply reduces relative reflectance. Conversely, higher proportions of high-absorption components like Fe 2 O 3 and C in dust lead to a steep increase in relative reflectance. This study quantifies the impact of dust accumulation on the optical performance of concentrators using the Monte Carlo Ray Tracing method, revealing a 20.4 % and 30.5 % efficiency reduction at a deposition density of 10 and 15 g/m 2 , and highlighting the critical role of dust composition in reflectivity and absorption. Based on these findings, a fitting formula is proposed to predict performance degradation and recommend an economic cleaning cycle of 20.8 to 61.1 days, providing a basis for the optimization of concentrated solar power systems in dust-prone regions. This research enhances the deployment and maintenance of concentrated solar power systems by elucidating the impact of dust accumulation on parabolic trough concentrator performance.

Solar EnergyVol. 300
Shandong University (CN), City University of Hong Kong, Shenzhen Research Institute (CN), Xi'an Jiaotong University (CN)
Climate action
Openalex Percentile: Top 41%
Solar Thermal and Photovoltaic Systems
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.