Sensitive integrated photonic transducer with predictive modeling for underwater ultrasound sensing

A high signal-to-noise ratio (SNR) is critical for sensitive ultrasound applications. Unlike traditional piezoelectric sensors that rely on material properties, an integrated photonic ultrasound transducer (IPUT) separates sensing and read-out systems, allowing for better optimization. Here we use a silicon Mach-Zehnder interferometer (MZI) embedded in a circular silicon dioxide membrane, where incident acoustic pressure modulates the optical phase. We extend the semi-analytical model introduced in our previous work to incorporate the device geometry and fabrication-induced internal stress, enabling accurate prediction of the transducer's optomechanical response. This approach resulted in an experimentally measured sensitivity of 0.47 pm/Pa at a resonance frequency near 1 MHz, in close agreement with the model prediction of 0.46 pm/Pa. This performance represents a sevenfold improvement over previously reported devices [Lienders et al., Sci. Rep., 2015]. Additionally, we have developed two more IPUTs where multiple membranes were cascaded and their performance was experimentally investigated. The IPUT with three membranes had an RTF of 1.4 pm/Pa, while the IPUT with five membranes' RTF was 2.24 pm/Pa. Our IPUTs also have excellent noise performance, as demonstrated by the noise equivalent pressure (NEP) of the device. NEP of IPUT with one membrane is 42.5 mPa, IPUT with three membranes is 15.5 mPa, and the IPUT with five membranes is 14.2 mPa. Compared to the state-of-the-art ultrasound sensors, our IPUT with five membrane shows 35 times lower NEP. Our results demonstrate that fabrication-aware modeling is crucial for achieving optimal sensitivity in IPUTs, establishing the proposed IPUT as a promising solution for underwater ultrasound sensing.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-08-04
DOI
https://doi.org/10.1364/oe.571595
Primary Topic
Photoacoustic and Ultrasonic Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensitive integrated photonic transducer with predictive modeling for underwater ultrasound sensing

Martin D. Verweij, Maurits van der Heiden, Sabiju Valiya Valappil, Robert Altmann et al.
Optics Express
Photoacoustic and Ultrasonic Imaging
article

Sensitive integrated photonic transducer with predictive modeling for underwater ultrasound sensing

Martin D. Verweij, Maurits van der Heiden, Sabiju Valiya Valappil, Robert Altmann, P.L.M.J. van Neer, P.J. Harmsma, Anne Maaike Gerritsma
article en

Abstract

A high signal-to-noise ratio (SNR) is critical for sensitive ultrasound applications. Unlike traditional piezoelectric sensors that rely on material properties, an integrated photonic ultrasound transducer (IPUT) separates sensing and read-out systems, allowing for better optimization. Here we use a silicon Mach-Zehnder interferometer (MZI) embedded in a circular silicon dioxide membrane, where incident acoustic pressure modulates the optical phase. We extend the semi-analytical model introduced in our previous work to incorporate the device geometry and fabrication-induced internal stress, enabling accurate prediction of the transducer's optomechanical response. This approach resulted in an experimentally measured sensitivity of 0.47 pm/Pa at a resonance frequency near 1 MHz, in close agreement with the model prediction of 0.46 pm/Pa. This performance represents a sevenfold improvement over previously reported devices [Lienders et al., Sci. Rep., 2015]. Additionally, we have developed two more IPUTs where multiple membranes were cascaded and their performance was experimentally investigated. The IPUT with three membranes had an RTF of 1.4 pm/Pa, while the IPUT with five membranes' RTF was 2.24 pm/Pa. Our IPUTs also have excellent noise performance, as demonstrated by the noise equivalent pressure (NEP) of the device. NEP of IPUT with one membrane is 42.5 mPa, IPUT with three membranes is 15.5 mPa, and the IPUT with five membranes is 14.2 mPa. Compared to the state-of-the-art ultrasound sensors, our IPUT with five membrane shows 35 times lower NEP. Our results demonstrate that fabrication-aware modeling is crucial for achieving optimal sensitivity in IPUTs, establishing the proposed IPUT as a promising solution for underwater ultrasound sensing.

Optics ExpressVol. 33(17)
Netherlands Organisation for Applied Scientific Research (NL), Dutch Research Council (NL)
Openalex Percentile: Top 82%
Photoacoustic and Ultrasonic Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.