Tailored Quantum Dots@Metal–Organic Frameworks for Enhanced Hypochlorite Detection in Live Cells and Ulcerative Colitis Diagnosis

Excess levels of hypochlorous acid/hypochlorite (HClO/ClO<sup>-</sup>) are associated with the development of tissue damage and the onset of various pathological conditions. The enzymatic reaction of myeloperoxidase produces HClO/ClO<sup>-</sup>, which is closely related to hepatic ulcerative colitis (UC). The detection of HClO is particularly important as it provides valuable insights into the early diagnosis of UC. In this study, we introduce a new class of quantum dot@metal-organic framework composites, specifically QD-PEI@ZIF-8, fabricated via the one-pot solvothermal method. These composites are based on aqueous quantum dots (QDs) of surface amine ligands (QD-PEI), which promote the epitaxial growth of zeolitic imidazolate framework (ZIF-8) structures. The resulting QD-PEI@ZIF-8 composites demonstrate enhanced optical properties and stability. The highly porous QD-PEI@ZIF-8 composites exhibit better specificity for ion selection and improve detection sensitivity. The fluorescence burst of the QD-PEI@ZIF-8 composite enabled highly specific detection of ClO<sup>-</sup>, covering a wide linear range from 10 to 120 μM, and its limit of detection (LOD) was improved to 0.38 μM, representing a 36-fold enhancement in sensitivity compared to the QD-PEI. Furthermore, the QD-PEI@ZIF-8 composite was validated for live cell imaging applications. By optimization of the detection conditions, a "sampling-detecting" capillary sensor for ClO<sup>-</sup> detection in the fecal samples from both mice and human subjects with UC disease was developed. This strategy provides a novel QD-PEI@ZIF-8 composite and capillary sensor for specific, sensitive, and efficient detection of HClO/ClO<sup>-</sup>, with implications for both cellular regulation and detection of UC diseases.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-08-04
DOI
https://doi.org/10.1021/acs.analchem.5c02246
Citations
2
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
1.51

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Tailored Quantum Dots@Metal–Organic Frameworks for Enhanced Hypochlorite Detection in Live Cells and Ulcerative Colitis Diagnosis

Xueyu Chen, Tianxin Li, Lin Song Li, Ruili Wu et al.
2 citations
Analytical Chemistry
Molecular Sensors and Ion Detection
1.51
article

Tailored Quantum Dots@Metal–Organic Frameworks for Enhanced Hypochlorite Detection in Live Cells and Ulcerative Colitis Diagnosis

Xueyu Chen, Tianxin Li, Lin Song Li, Ruili Wu, Huaibin Shen, Yanbing Lv, Shizhen Zhao, Yuning Zhang, Nan Jiang, Yingli Ye
article en
2 citations

Abstract

Excess levels of hypochlorous acid/hypochlorite (HClO/ClO<sup>-</sup>) are associated with the development of tissue damage and the onset of various pathological conditions. The enzymatic reaction of myeloperoxidase produces HClO/ClO<sup>-</sup>, which is closely related to hepatic ulcerative colitis (UC). The detection of HClO is particularly important as it provides valuable insights into the early diagnosis of UC. In this study, we introduce a new class of quantum dot@metal-organic framework composites, specifically QD-PEI@ZIF-8, fabricated via the one-pot solvothermal method. These composites are based on aqueous quantum dots (QDs) of surface amine ligands (QD-PEI), which promote the epitaxial growth of zeolitic imidazolate framework (ZIF-8) structures. The resulting QD-PEI@ZIF-8 composites demonstrate enhanced optical properties and stability. The highly porous QD-PEI@ZIF-8 composites exhibit better specificity for ion selection and improve detection sensitivity. The fluorescence burst of the QD-PEI@ZIF-8 composite enabled highly specific detection of ClO<sup>-</sup>, covering a wide linear range from 10 to 120 μM, and its limit of detection (LOD) was improved to 0.38 μM, representing a 36-fold enhancement in sensitivity compared to the QD-PEI. Furthermore, the QD-PEI@ZIF-8 composite was validated for live cell imaging applications. By optimization of the detection conditions, a "sampling-detecting" capillary sensor for ClO<sup>-</sup> detection in the fecal samples from both mice and human subjects with UC disease was developed. This strategy provides a novel QD-PEI@ZIF-8 composite and capillary sensor for specific, sensitive, and efficient detection of HClO/ClO<sup>-</sup>, with implications for both cellular regulation and detection of UC diseases.

Analytical ChemistryVol. 97(31)
Henan University (CN), Washington University in St. Louis (US), Preston University (US), Institute of Molecular Functional Materials (CN)
National Natural Science Foundation of China, Science and Technology Department of Henan Province
Zero hunger
Openalex Percentile: Top 17%
Molecular Sensors and Ion Detection
1.51
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.