Numerical Considerations on Design Parameters of Diffuser Vane Slit

In this study, CFD simulations were conducted to investigate the optimal design parameters for the diffuser vane slit, which is one of the means to suppress diffuser rotating stall (DRS), in terms of slit width, height, and position, to maximize the DRS suppression effect while maintaining diffuser performance. The investigated pump is a centrifugal pump with a specific speed of Ns = 138 m 3 /min, m, rpm and the diffuser is an axial-flow type. The simple prediction method of DRS by CFD simulation used in the previous study was applied and evaluated in terms of the coefficient of variation C . V ., static pressure recovery coefficient C P , and total pressure loss coefficient C T in the diffuser flow channel. As a result, it was found that the slit position was the best at 18% of the vane axial chord length regardless of the slit width, and that the slit height from the hub to the tip provided the best DRS suppression. A wider slit width increases the flow rate through the slit and enhances the DRS suppression effect, but it causes lower diffuser performance and results in a trade-off relationship. Therefore, the slit width should be set to an appropriate value depending on the required operating range.

Authors

Institutions

Publication Details

Journal
Advances in science and technology
Published
2025-08-04
DOI
https://doi.org/10.4028/p-0pvc5h
Primary Topic
Turbomachinery Performance and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Considerations on Design Parameters of Diffuser Vane Slit

Shinichiro Ejiri, Masahiro MIYABE, Dai IWASAKI
Advances in science and technology
Turbomachinery Performance and Optimization
article

Numerical Considerations on Design Parameters of Diffuser Vane Slit

Shinichiro Ejiri, Masahiro MIYABE, Dai IWASAKI
article en

Abstract

In this study, CFD simulations were conducted to investigate the optimal design parameters for the diffuser vane slit, which is one of the means to suppress diffuser rotating stall (DRS), in terms of slit width, height, and position, to maximize the DRS suppression effect while maintaining diffuser performance. The investigated pump is a centrifugal pump with a specific speed of Ns = 138 m 3 /min, m, rpm and the diffuser is an axial-flow type. The simple prediction method of DRS by CFD simulation used in the previous study was applied and evaluated in terms of the coefficient of variation C . V ., static pressure recovery coefficient C P , and total pressure loss coefficient C T in the diffuser flow channel. As a result, it was found that the slit position was the best at 18% of the vane axial chord length regardless of the slit width, and that the slit height from the hub to the tip provided the best DRS suppression. A wider slit width increases the flow rate through the slit and enhances the DRS suppression effect, but it causes lower diffuser performance and results in a trade-off relationship. Therefore, the slit width should be set to an appropriate value depending on the required operating range.

Advances in science and technologyVol. 169
Nikkiso (Japan) (JP), Osaka Institute of Technology (JP)
Openalex Percentile: Top 73%
Turbomachinery Performance and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical Considerations on Design Parameters of Diffuser Vane Slit — Shinichiro Ejiri, Masahiro MIYABE, et al. · Advances in science and technology (2025) | TGRS Research Map | TGRS