Nanostructured Bismuth-Doped Cobalt Ferrite (Bi<sub><i>x</i></sub>CoFe<sub>2</sub>O<sub>4</sub>) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring

Globally, cardiovascular disease (CVD) constitute a primary source of morbidity and mortality. Timely and precise diagnosis of pertinent biomarkers and function parameters can provide valuable insight into the physiological and pathological processes associated with CVD. This research aims to develop a new sensing platform for C-reactive protein (CRP) to detect cardiovascular disease, utilizing an indium tin oxide (ITO) electrode modified with hydrothermally synthesized bismuth-doped cobalt ferrite (Bi<sub><i>x</i></sub>CoFe<sub>2</sub>O<sub>4</sub>) nanoparticles (NPs) by varying bismuth concentrations of (<i>x</i> = 0.5, 0.10, 0.15, 0.20 M). These synthesized doped NPs are characterized by using XRD, FTIR, UV, scanning electron microscopy (SEM), HR-TEM, energy-dispersive X-ray (EDX), dynamic light scattering (DLS), and AFM techniques to ascertain their morphological and structural properties. The modified material was deposited on the ITO electrode via the electrophoretic deposition (EPD) method. The electrochemical study indicates that the modified electrode exhibits a higher current density than the bare ITO electrode. CRP immobilization was performed by the drop casting method, and the electrochemical impedance spectroscopy (EIS) demonstrates that the developed immunoelectrode exhibits a linear concentration at a lower range from 0.5 to 100 ng/mL and a higher range of 100-500 ng/mL. The sensitivity has been observed at 0.376305 and 0.05492 Ω/ng cm<sup>2</sup>, with the limit of detection (LOD) of 0.15 and 0.22 ng/mL, the limit of quantification (LOQ) of 0.51 and 0.74 ng/mL, and the response time of 20 s. The study is significant in the field of CVD, as it assesses inflammation and cardiovascular risk.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-08-04
DOI
https://doi.org/10.1021/acs.langmuir.5c01951
Citations
2
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
1.46

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nanostructured Bismuth-Doped Cobalt Ferrite (BixCoFe2O4) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring

Astha Singh, Jay Singh, Sarita Shaktawat, N. B. Singh et al.
2 citations
Langmuir
Electrochemical sensors and biosensors
1.46
article

Nanostructured Bismuth-Doped Cobalt Ferrite (BixCoFe2O4) Interfaces for the Impedimetric Detection of C-Reactive Protein in Cardiovascular Disease Monitoring

Astha Singh, Jay Singh, Sarita Shaktawat, N. B. Singh, Sher Singh
article en
2 citations

Abstract

Globally, cardiovascular disease (CVD) constitute a primary source of morbidity and mortality. Timely and precise diagnosis of pertinent biomarkers and function parameters can provide valuable insight into the physiological and pathological processes associated with CVD. This research aims to develop a new sensing platform for C-reactive protein (CRP) to detect cardiovascular disease, utilizing an indium tin oxide (ITO) electrode modified with hydrothermally synthesized bismuth-doped cobalt ferrite (Bi<sub><i>x</i></sub>CoFe<sub>2</sub>O<sub>4</sub>) nanoparticles (NPs) by varying bismuth concentrations of (<i>x</i> = 0.5, 0.10, 0.15, 0.20 M). These synthesized doped NPs are characterized by using XRD, FTIR, UV, scanning electron microscopy (SEM), HR-TEM, energy-dispersive X-ray (EDX), dynamic light scattering (DLS), and AFM techniques to ascertain their morphological and structural properties. The modified material was deposited on the ITO electrode via the electrophoretic deposition (EPD) method. The electrochemical study indicates that the modified electrode exhibits a higher current density than the bare ITO electrode. CRP immobilization was performed by the drop casting method, and the electrochemical impedance spectroscopy (EIS) demonstrates that the developed immunoelectrode exhibits a linear concentration at a lower range from 0.5 to 100 ng/mL and a higher range of 100-500 ng/mL. The sensitivity has been observed at 0.376305 and 0.05492 Ω/ng cm<sup>2</sup>, with the limit of detection (LOD) of 0.15 and 0.22 ng/mL, the limit of quantification (LOQ) of 0.51 and 0.74 ng/mL, and the response time of 20 s. The study is significant in the field of CVD, as it assesses inflammation and cardiovascular risk.

LangmuirVol. 41(31)
Sam Higginbottom Institute of Agriculture (IN), Shanghai Institute for Science of Science (CN), Banaras Hindu University (IN)
Banaras Hindu University
Openalex Percentile: Top 16%
Electrochemical sensors and biosensors
1.46
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.