Pulse duration stability in the SG-II picosecond-petawatt laser system

Abstract The pulse duration is a critical parameter of picosecond-petawatt laser systems because it directly affects the results of high-energy-density physics experiments. This study systematically investigated the effects of the spectral width, central wavelength and beam-pointing deviations on pulse duration stability at the SG-II facility. A theoretical analysis of the relationship between spectra and pulse duration is conducted to quantify the impact on pulse duration stability, and the results are further validated through experimental measurements. In addition, beam-pointing deviations at the stretcher significantly affect the pulse duration. For example, a 27 μrad deviation can induce a 30% pulse duration variation. In contrast, the compressor exhibits greater robustness. Based on simulation and experimental results, we identify operational tolerance ranges for spectral width and beam-pointing deviation to maintain pulse duration stability within 5% at the SG-II facility. These findings provide critical guidance for optimizing the performance and reliability of chirped-pulse amplification/optical parametric chirped-pulse amplification-based high-power laser systems.

Authors

Institutions

Publication Details

Journal
High Power Laser Science and Engineering
Published
2025-01-01
DOI
https://doi.org/10.1017/hpl.2025.10057
Primary Topic
Laser Design and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulse duration stability in the SG-II picosecond-petawatt laser system

Dajie Huang, Fucai Ding, Pan Xue, Junyi Liu et al.
High Power Laser Science and Engineering
Laser Design and Applications
article

Pulse duration stability in the SG-II picosecond-petawatt laser system

Dajie Huang, Fucai Ding, Pan Xue, Junyi Liu, Xiaoping Ouyang, Wei Fan, Ke Hou, Jianqiang Zhu, Guoli Zhang, Youen Jiang
article en

Abstract

Abstract The pulse duration is a critical parameter of picosecond-petawatt laser systems because it directly affects the results of high-energy-density physics experiments. This study systematically investigated the effects of the spectral width, central wavelength and beam-pointing deviations on pulse duration stability at the SG-II facility. A theoretical analysis of the relationship between spectra and pulse duration is conducted to quantify the impact on pulse duration stability, and the results are further validated through experimental measurements. In addition, beam-pointing deviations at the stretcher significantly affect the pulse duration. For example, a 27 μrad deviation can induce a 30% pulse duration variation. In contrast, the compressor exhibits greater robustness. Based on simulation and experimental results, we identify operational tolerance ranges for spectral width and beam-pointing deviation to maintain pulse duration stability within 5% at the SG-II facility. These findings provide critical guidance for optimizing the performance and reliability of chirped-pulse amplification/optical parametric chirped-pulse amplification-based high-power laser systems.

High Power Laser Science and EngineeringVol. 13
Shanghai Institute of Optics and Fine Mechanics (CN), University of Chinese Academy of Sciences (CN)
National Natural Science Foundation of China, Chinese Academy of Sciences
Affordable and clean energy
Openalex Percentile: Top 83%
Laser Design and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.