Study on the Performance of MXene-Cu<sub>2</sub>O Composites in Detecting NO<sub>2</sub> Gas at Room Temperature

针对传统NO2检测技术依赖高温、灵敏度不足等问题,本研究通过水热法制备了MXene-Cu2O复合材料,开发了一种新型室温下超灵敏气体传感器。实验表明,传感器在室温下展现出宽线性检测范围、低检测限及优异抗干扰性,可稳定检测ppb至ppm级NO2。该研究为开发低功耗、高灵敏的室温气体传感器提供了新策略,在环境监测与工业安全领域具有重要应用价值。To address the limitations of conventional NO2 detection technologies, such as high-temperature operation and insufficient sensitivity, this study developed a novel room-temperature ultrasensitive gas sensor based on MXene-Cu2O composites synthesized via a hydrothermal method. Experimental results demonstrate that the sensor exhibits a wide linear detection range, low detection limit, and excellent anti-interference capability, enabling stable detection of NO2 from ppb to ppm levels at room temperature. This research provides a new strategy for designing low-power, high-sensitivity room-temperature gas sensors, offering significant application potential in environmental monitoring and industrial safety fields.

Authors

Publication Details

Journal
Advances in Condensed Matter Physics
Published
2025-01-01
DOI
https://doi.org/10.12677/cmp.2025.143003
Primary Topic
MXene and MAX Phase Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Performance of MXene-Cu2O Composites in Detecting NO2 Gas at Room Temperature

元杞 宋
4 links
Advances in Condensed Matter Physics
MXene and MAX Phase Materials
article

Study on the Performance of MXene-Cu2O Composites in Detecting NO2 Gas at Room Temperature

元杞 宋
article en

Abstract

针对传统NO2检测技术依赖高温、灵敏度不足等问题,本研究通过水热法制备了MXene-Cu2O复合材料,开发了一种新型室温下超灵敏气体传感器。实验表明,传感器在室温下展现出宽线性检测范围、低检测限及优异抗干扰性,可稳定检测ppb至ppm级NO2。该研究为开发低功耗、高灵敏的室温气体传感器提供了新策略,在环境监测与工业安全领域具有重要应用价值。To address the limitations of conventional NO2 detection technologies, such as high-temperature operation and insufficient sensitivity, this study developed a novel room-temperature ultrasensitive gas sensor based on MXene-Cu2O composites synthesized via a hydrothermal method. Experimental results demonstrate that the sensor exhibits a wide linear detection range, low detection limit, and excellent anti-interference capability, enabling stable detection of NO2 from ppb to ppm levels at room temperature. This research provides a new strategy for designing low-power, high-sensitivity room-temperature gas sensors, offering significant application potential in environmental monitoring and industrial safety fields.

Advances in Condensed Matter PhysicsVol. 14(03)
Openalex Percentile: Top 86%
MXene and MAX Phase Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.