The Dangerous Feature Identification of Transmission Line Galloping Under Multi-channel Modal State

A rough set combined with an ant colony algorithm is used to extract the non-forced vibration signal from the measured transmission line galloping displacement signal, which is used as the risk feature recognition index. In the real model test, the transmission line's six split line segment shift time history is measured across multiple channels to identify the galloping frequency, vibration mode, and damping ratio of the transmission line. At the same time, MATLAB simulation is employed to verify the algorithm's accuracy and computation time. The results show that the accuracy of the proposed algorithm in identifying the galloping frequency, vibration mode, and damping ratio is 98%, 97.6%, and 98.5%, respectively, with calculation times of 16s, 18s, and 17.5s. Therefore, in multi-channel modal analysis, a rough set combined with the ant colony algorithm can effectively address the problem of dangerous feature identification of transmission line galloping.

Authors

Institutions

Publication Details

Journal
Renewable Energy and Power Quality Journal
Published
2025-08-04
DOI
https://doi.org/10.52152/4325
Primary Topic
Vibration and Dynamic Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Dangerous Feature Identification of Transmission Line Galloping Under Multi-channel Modal State

Zhimeng Zhang, Xiaoyu Yi, Cuiying Sun, Yixin Wang et al.
Renewable Energy and Power Quality Journal
Vibration and Dynamic Analysis
article

The Dangerous Feature Identification of Transmission Line Galloping Under Multi-channel Modal State

Zhimeng Zhang, Xiaoyu Yi, Cuiying Sun, Yixin Wang, Jie Liu
article en

Abstract

A rough set combined with an ant colony algorithm is used to extract the non-forced vibration signal from the measured transmission line galloping displacement signal, which is used as the risk feature recognition index. In the real model test, the transmission line's six split line segment shift time history is measured across multiple channels to identify the galloping frequency, vibration mode, and damping ratio of the transmission line. At the same time, MATLAB simulation is employed to verify the algorithm's accuracy and computation time. The results show that the accuracy of the proposed algorithm in identifying the galloping frequency, vibration mode, and damping ratio is 98%, 97.6%, and 98.5%, respectively, with calculation times of 16s, 18s, and 17.5s. Therefore, in multi-channel modal analysis, a rough set combined with the ant colony algorithm can effectively address the problem of dangerous feature identification of transmission line galloping.

Renewable Energy and Power Quality JournalVol. 23(6)
Electric Power Research Institute (US)
Openalex Percentile: Top 78%
Vibration and Dynamic Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Dangerous Feature Identification of Transmission Line Galloping Under Multi-channel Modal State — Zhimeng Zhang, Xiaoyu Yi, et al. · Renewable Energy and Power Quality Journal (2025) | TGRS Research Map | TGRS