A new self-calibrating infrasound sensor design

We will present the results of testing a new self-calibrating infrasound sensor design, developed by Hyperion. This design integrates a sound source and system controller logic into the body of a Hyperion infrasound sensor. Both analog and digital versions of this design were constructed and tested. The calibrator produces a sinusoidal pressure signal with amplitude and frequency specified by the user into the back volume of the infrasound sensor. The calibration controller corrects for static pressure and temperature effects on the pressure source, and the system can be operated fully remotely. Results of testing of this system will be presented along with a discussion of possible improvements of this design, including improvements in methodology which would make this system more directly traceable in a metrological sense.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2025-04-01
DOI
https://doi.org/10.1121/10.0038193
Primary Topic
Seismic Waves and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new self-calibrating infrasound sensor design

David E. Harris, Carrick L. Talmadge, Joshua R. McConnell Parsons, Hank Buchanan et al.
The Journal of the Acoustical Society of America
Seismic Waves and Analysis
article

A new self-calibrating infrasound sensor design

David E. Harris, Carrick L. Talmadge, Joshua R. McConnell Parsons, Hank Buchanan, Chad M. Williams, JaqWan Works
article en

Abstract

We will present the results of testing a new self-calibrating infrasound sensor design, developed by Hyperion. This design integrates a sound source and system controller logic into the body of a Hyperion infrasound sensor. Both analog and digital versions of this design were constructed and tested. The calibrator produces a sinusoidal pressure signal with amplitude and frequency specified by the user into the back volume of the infrasound sensor. The calibration controller corrects for static pressure and temperature effects on the pressure source, and the system can be operated fully remotely. Results of testing of this system will be presented along with a discussion of possible improvements of this design, including improvements in methodology which would make this system more directly traceable in a metrological sense.

The Journal of the Acoustical Society of AmericaVol. 157(4_Supplement)
University of Mississippi (US), Hyperion Technology Group (United States) (US), Hyperion Technologies (Canada) (CA)
Openalex Percentile: Top 80%
Seismic Waves and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.